Advanced Aortic Imaging after Surgery for Acute Aortic Dissection

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17472 

Submission Type:

Abstract Submission 

Authors:

Fadi Al-Zubaidi (1), George Krasopoulos (1), Saul Myerson (1), Dominic Howard (1), Fabian Hundertmark (1), Ujjawal Kumar (1), Arian Arjomandi Rad (1), Sarvananthan Sajiram (1), Alex Pitcher (1), Rafiuddin Patel (1), Ed Sideso (1), Raman Uberoi (1)

Institutions:

(1) John Radcliffe Hospital, Oxford, United Kingdom

Submitting Author:

Fadi Al-Zubaidi    -  Contact Me
John Radcliffe Hospital

Co-Author(s):

George Krasopoulos    -  Contact Me
John Radcliffe Hospital
Saul Myerson    -  Contact Me
John Radcliffe Hospital
Dominic Howard    -  Contact Me
John Radcliffe Hospital
Fabian Hundertmark    -  Contact Me
John Radcliffe Hospital
Ujjawal Kumar    -  Contact Me
John Radcliffe Hospital
Arian Arjomandi Rad    -  Contact Me
John Radcliffe Hospital
Sarvananthan Sajiram    -  Contact Me
John Radcliffe Hospital
Alex Pitcher    -  Contact Me
John Radcliffe Hospital
Rafiuddin Patel    -  Contact Me
John Radcliffe Hospital
Ed Sideso    -  Contact Me
John Radcliffe Hospital
Raman Uberoi    -  Contact Me
John Radcliffe Hospital

Presenting Author:

Fadi Al-Zubaidi    -  Contact Me
John Radcliffe Hospital

Abstract:

Objectives
Surveillance after acute aortic dissection (AAD) repair relies mainly on maximal aortic diameter, an imprecise and lagging predictor of progression. This scoping review maps evidence for four dimensional (4D) flow magnetic resonance imaging (MRI), 4D computed tomography (CT), computational fluid dynamics (CFD) and fluid structure interaction (FSI) modelling, identifying which haemodynamic parameters have been evaluated, what they predict, and whether they could stratify risk beyond size.

Methods
Reported per PRISMA 2020 and its scoping review extension. PubMed/MEDLINE, Embase, SCOPUS and Cochrane databases were searched from inception to 5 July 2026; sources reporting haemodynamic parameters after open or endovascular repair of AAD were eligible.

Results
Of 1118 records, 109 met eligibility criteria; most haemodynamic data came from 4D flow MRI and CFD/FSI, with 4D CT contributing morphology only. Systolic false lumen (FL) flow above 30% of total aortic flow, FL ejection fraction, elevated FL pressure gradients and abnormal time averaged wall shear stress or oscillatory shear index were associated with adverse remodelling, stent graft induced new entry and reintervention. Effect sizes were often large but from small cohorts: a high risk FL flow pattern gave an adjusted hazard ratio of 16.87 for aorta related events (n=131); FL ejection fraction correlated with growth (r=0.78) and relative pressure inversely (r=0.64); deep learning predicted distal remodelling and reintervention after endovascular repair (AUC 0.88 and 0.81).

Conclusions
1. Advanced images offers the potential for more personalised and targeted surveillance protocols.
2. Haemodynamic parameters from 4D flow MRI, 4D CT and CFD/FSI add mechanistic and predictive information not captured by diameter, but the evidence rests on small single centre cohorts.
3. Standardised protocols and prospective multicentre validation against hard outcomes are needed.

Aortic Symposium:

Natural History/Follow-Up

 

Keywords - Adult

Guidelines
Aorta - Aorta
Aorta - Aortic Arch
Aorta - Aortic Disection
Imaging - Imaging