Association Between Thoracic Stent-Graft Design and Major Proximal Device Failure After Hybrid Aortic Arch Repair
Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17475
Submission Type:
Abstract Submission
Authors:
Victor Mosquera Rodriguez (1), Jose M Martinez-Comendador (1), Miguel Barbeito González (1), Barbara Oujo Gonzalez (1), carlos velasco (1), Jose J. Cuenca Castillo (1)
Institutions:
(1) University Hospital of A Coruña, A Coruña, Spain
Submitting Author:
Victor Mosquera Rodriguez
-
Contact Me
University Hospital of A Coruña
Co-Author(s):
Jose M Martinez-Comendador
-
Contact Me
University Hospital of A Coruña
Miguel Barbeito González
-
Contact Me
University Hospital of A Coruña
Barbara Oujo Gonzalez
-
Contact Me
University Hospital of A Coruña
carlos velasco
-
Contact Me
University Hospital of A Coruña
Jose J. Cuenca Castillo
-
Contact Me
University Hospital of A Coruña
Presenting Author:
Victor Mosquera Rodriguez
-
Contact Me
Department of Cardiac Surgery, University Hospital of A Coruña, A Coruña, Spain
Abstract:
Objective: To evaluate whether thoracic stent-graft design is associated with major proximal device-related failure after hybrid aortic arch repair combining supra-aortic debranching or translocation with thoracic endovascular aortic repair.
Methods: We retrospectively analyzed 110 consecutive high-risk patients who underwent conventional hybrid aortic arch repair between January 2010 and January 2025. Procedures consisted of supra-aortic debranching or translocation followed by thoracic endovascular aortic repair with proximal landing in Ishimaru zones 0–2. The primary endpoint was major proximal device-related failure, defined as type Ia or III endoleak, retrograde type A dissection, endograft infection, or aortobronchial fistula requiring reintervention. In-hospital mortality was analyzed separately. Device-related event rates were compared using Fisher's exact test, followed by an exploratory Cochran-Armitage trend analysis. Event-free survival was assessed using Kaplan-Meier analysis and the log-rank test.
Results: The cohort included 110 patients (mean age 65.0 years; 88/110 [80%] men) with a mean follow-up of 69.3 months. In-hospital mortality was 6/110 (5.5%) and stroke occurred in 3/110 patients (2.7%). Major proximal device-related failure occurred in 16/110 patients (14.5%), comprising 10 type Ia or III endoleaks, 3 retrograde type A dissections, 2 endograft infections, and 1 aortobronchial fistula; all required reintervention (8 open, 8 endovascular). Event rates were 1/30 (3.3%), 5/34 (14.7%), and 10/46 (21.7%) across the three stent-graft design groups. Compared with the pooled comparator group, the lowest-event design was associated with a lower risk of major proximal device-related failure (odds ratio 0.15; 95% confidence interval 0.02–0.97; P=0.041). An exploratory trend analysis demonstrated increasing event rates across designs (P=0.011). Event-free survival also differed significantly among groups (log-rank P=0.020).
Conclusions: Major proximal device-related failure was the principal determinant of late treatment failure after conventional hybrid aortic arch repair. Thoracic stent-graft design was associated with different rates of proximal device-related failure and reintervention. These hypothesis-generating findings support further multicenter studies to determine whether device design independently influences long-term durability after hybrid aortic arch repair.