Y-Incision Aortic Annular Enlargement: Operative Outcomes and a Novel Pattern of Mitral Regurgitation in 52 Consecutive Patients

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17545 

Submission Type:

Abstract Submission 

Authors:

Tom Friedman (1), Nadav Willner (2), Anastasia Vialkin (3), Benjamin Medalion (1)

Institutions:

(1) Department of Cardiac Surgery, Rambam Health Care Campus, Haifa, Israel, (2) Department Of Cardiology, Rambam Health Care Campus, Haifa, Israel, (3) Department of cardiac surgery, Rambam Health Care Campus, Haifa, Israel

Submitting Author:

Tom Friedman    -  Contact Me
Department of Cardiac Surgery, Rambam Health Care Campus

Co-Author(s):

Nadav Willner    -  Contact Me
Department Of Cardiology, Rambam Health Care Campus
Anastasia Vialkin    -  Contact Me
Department of cardiac surgery, Rambam Health Care Campus
Benjamin Medalion    -  Contact Me
Department of Cardiac Surgery, Rambam Health Care Campus

Presenting Author:

Tom Friedman    -  Contact Me
Rambam

Abstract:

Objective: Y-incision aortic annular enlargement enables upsizing the aortic prosthesis by two to five valve sizes and has been advocated to prevent patient–prosthesis mismatch. Data from centers beyond the originating group remain scarce, and mitral regurgitation (MR) as a complication of the technique has not been systematically studied.
Methods: We retrospectively reviewed 52 consecutive patients undergoing surgical aortic valve replacement (SAVR) with Y-incision annular enlargement at a single tertiary cardiac surgery center between October 2022 and July 2026. Outcomes were compared against the full institutional aortic valve replacement (AVR) cohort from the same center (2015–2025; n=765 for 30-day mortality, n=518 with paired preoperative and first postoperative echocardiograms for MR analysis). MR deterioration was defined as a worsening of ≥2 grade steps, resulting in at least moderate MR. Patients with and without MR deterioration were compared using the Mann–Whitney U test and Fisher's exact test.
Results: Mean age was 65.3 ± 6.9 years; 75.0% were female; mean EuroSCORE II was 5.0 ± 4.6%. Operative mortality was 4/52 (7.7%), not significantly different from the institutional AVR rate of 6.9% (53/765; OR 1.12, p=0.778), despite higher predicted risk and a greater rate of concomitant procedures 19/52 (37%) vs 239/765 (31.2%). Clinically significant MR deterioration occurred in 5/52 patients (9.6%), significantly higher than the institutional AVR rate of 3.3% (17/518; OR 3.14, p=0.041). Patients with MR deterioration had a significantly smaller native aortic annulus than those without (19.6 ± 0.9 mm vs 21.1 ± 1.2 mm; p=0.011). MR improved in one patient and persisted in three; one patient required urgent mitral valve replacement and died.
Conclusions: Y-incision AAE yielded mortality concordant with institutional AVR rates and EuroSCORE II prediction. The rate of significant MR deterioration was significantly higher than the institutional baseline (9.6% vs 3.3%; p=0.041) and was associated with a smaller native aortic annulus (p=0.011), not prosthesis jump alone. Systematic echocardiographic surveillance is recommended, particularly in women with native annuli ≤20 mm.

Aortic Symposium:

Aortic Root

 

Keywords - Adult

Adult
Aorta - Aorta
Aorta - Aortic Root
Mitral Valve - Mitral Valve