Association between preoperative ascending aortic diameter and proximal anastomotic dehiscence after surgical repair of acute type A aortic dissection

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17601 

Submission Type:

Abstract Submission 

Authors:

Keisuke Kawaida (1), Yoshiharu Soga (1)

Institutions:

(1) Department of Cardiovascular Surgery, Kagoshima University, Kagoshima, Japan

Submitting Author:

Keisuke Kawaida    -  Contact Me
Department of Cardiovascular Surgery, Kagoshima University

Co-Author:

Yoshiharu Soga    -  Contact Me
Department of Cardiovascular Surgery, Kagoshima University

Presenting Author:

Keisuke Kawaida    -  Contact Me
N/A

Abstract:

Background
Although several reports have described proximal reoperations following surgery for acute type A aortic dissection (ATAAD), few studies have focused specifically on proximal anastomotic dehiscence (PADE), including pseudoaneurysm and re-dissection, and their predictors remain unknown. This study aimed to analyze the association between preoperative ascending aortic diameter (AD) and PADE following surgical repair of ATAAD.
Methods
This single-center, retrospective study evaluated 109 of 156 patients who underwent surgery for acute type A aortic dissection (ATAAD) at our institution between April 2011 and December 2024. To analyze the association between preoperative AD and PADE following ATAAD repair, we compared 26 patients who developed PADE during postoperative follow-up (Group P) with 83 patients without PADE (Group N). PADE was defined as the presence of contrast material outside the true lumen at the suture line on contrast-enhanced computed tomography (CT). AD was measured at the level of the inferior edge of the right pulmonary artery in the short-axis view on preoperative CT. Rates of freedom from PADE were estimated using the Kaplan-Meier method. A Cox proportional hazards analysis for PADE was performed using age, sex, AD, and variables with significant differences (p<0.05) between the two groups.
Results
Patient characteristics, including age and sex, were comparable between the two groups. The median follow-up duration was 364 days in Group N, whereas the median time to PADE development was 792 days in Group P (p=0.097). BioGlue was used in nearly all patients (100% in Group P vs. 95.1% in Group N, p=0.582). The median AD was significantly larger in Group P than in Group N (50.2 mm [IQR 48.15–52.9] vs. 47.2 mm [IQR 43.9–50.0], p=0.012). Group P showed a significantly higher incidence of postoperative mediastinitis (15.4% vs. 3.6%, p=0.043). The rates of freedom from PADE at 1, 2, and 3 years were 87.0%, 83.4%, and 77.2%, respectively. Cox proportional hazards regression analysis revealed that AD was significantly associated with PADE (hazard ratio, 1.124; 95% confidence interval, 1.022–1.240; p=0.015).
Conclusions
Preoperative ascending aortic diameter (AD) might be a predictor of PADE after ATAAD repair. AD should be carefully accounted for as a potential confounder when evaluating other variables such as anastomotic techniques and the use of biologic glue in future investigations.

Aortic Symposium:

Dissection

Presentation

AATSabstract.pptx
 

Keywords - Adult

Aorta - Aortic Disection