Objective: To compare computed tomography angiography (CTA) with intraoperative measurements of the aortic root in tricuspid aortic valves with dilated roots, and to develop and validate an algorithm using CTA data to plan aortic valve sparing procedures.
Methods: Twenty-four consecutive patients undergoing aortic valve sparing surgery were studied in four steps. End-diastolic ECG-gated CTA was used to measure geometric cusp heights, basal ring diameter, free margin lengths and commissural heights. A semi-automated algorithm then combined these with a chosen target effective height to propose graft size, target basal ring diameter, commissural distribution along the graft perimeter and cusp plications. Surgery followed this plan using a straight vascular graft, with the same dimensions remeasured intraoperatively. Postoperative three-dimensional transesophageal echocardiography assessed effective cusp height, basal ring perimeter and degree of aortic regurgitation. Measurements were compared using a paired-samples Student t test.
Results: Median age was 67 years (range 35-78), 20 patients (83%) were male and median root diameter 55 mm (range 41-96). Procedures were remodeling in 12 (50%), reimplantation in 5 (21%), sinotubular junction remodeling with annuloplasty in 5 (21%) and valve replacement in 2 (8%). CTA and intraoperative basal ring diameter did not differ (27.2±2.3 vs 27.4±2.0 mm, n=18, p=0.433), nor did free margin lengths (all p>0.25). Geometric height was underestimated by CTA for all three cusps (p<0.001 each), with a larger discrepancy in prolapsing than non-prolapsing cusps (2.83±1.28 vs 0.95±1.0 mm, n=8 vs 52 cusps, p<0.001). Postoperative effective cusp height matched the target (9.8±0.8 vs 10.0±0.9 mm, n=17, p=0.232), as did basal ring diameter (24.1±1.6 vs 24.5±1.3 mm, p=0.065). Graft size and commissural distribution followed the plan in all 22 repairs (100%); deviations were limited to small cusp plications (left and non-coronary cusp, 3/22, 14% each). Regurgitation after repair was none or trace in 18 of 22 patients (82%) and mild in 4 (18%).
Conclusions: CTA accurately measures basal ring diameter and free margin length but underestimates cusp geometric height, particularly in prolapsing cusps. A CTA-based planning algorithm reliably predicted graft size, commissural distribution and effective cusp height, and may make aortic valve sparing surgery more reproducible.