Y-Incision Aortic Annular Enlargement as a Platform for Future ViV TAVI
Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17641
Submission Type:
Abstract Submission
Authors:
Joshua Schwartz (1), Adel Alqabandi (1), Tara D'Ignazio (1), Ibrahim Alranini (1), Abdulrahman Alhalees (1), Jean Buithieu (1), Josephine Pressacco (1), Giuseppe Martucci (1), Kevin Lachapelle (1)
Institutions:
(1) McGill University, Montreal, Canada
Submitting Author:
Co-Author(s):
Abdulrahman Alhalees
-
Contact Me
McGill University
Josephine Pressacco
-
Contact Me
McGill University
Presenting Author:
Joshua Schwartz
-
Contact Me
Emory Saint Joseph's Hospital
Abstract:
Objective
Patient-prosthesis mismatch (PPM) is a limitation of surgical aortic valve replacement (SAVR), particularly in patients with a small aortic annulus. Y-incision aortic annular enlargement (AAE) permits implantation of larger surgical prostheses. We examined mid-term hemodynamics and feasibility of valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) post SAVR with AAE.
Methods
From November 2021 to February 2025, 31 consecutive patients underwent SAVR with Y-incision AAE at the Royal Victoria Hospital. Clinical and echocardiographic follow-up was 100% complete. Postoperative imaging assessed prosthetic valve hemodynamics, PPM, and suitability for future ViV TAVI.
Results
Mean age was 70 ± 7 years, 65% were female, and mean body mass index was 31 ± 9 kg/m². There was no 30-day mortality and two late non-cardiac deaths occurred (6.5%). AAE increased median left ventricular outflow tract (LVOT) diameter from 20 ± 2 to 24 ± 2 mm, with 25 of 31 patients receiving prostheses with internal diameters larger than their native LVOT. At a median follow-up of 2.6 years, median (IQR) indexed effective orifice area was 0.9 cm² (0.8–1.0), with a mean transvalvular gradient of 11 mm Hg (7–16). Using manufacturer charts intra-operatively, 61% of patients were predicted to develop PPM. Following AAE and implantation of a larger prosthesis, 7 patients (23%) had moderate PPM and 2 (6%) had severe PPM at follow-up. At baseline, 10 of 19 patients (53%) who underwent TAVI assessment had unsuitable anatomy. Following AAE, 24 of 27 patients (89%) with postoperative scans assessed had suitable anatomy for ViV TAVI. Predicted median (IQR) valve size was 29 (26–29) mm for Evolut and 26 (23–26) mm for Sapien.
Conclusion
Y-incision AAE enables implantation of larger surgical prostheses in patients with small aortic annuli, resulting in favorable mid-term hemodynamics and a lower incidence of PPM than predicted. By creating a larger surgical valve platform, AAE may facilitate implantation of an appropriately sized ViV TAVI, expanding options for lifetime management of valve disease.