Y-Incision Aortic Annular Enlargement as a Platform for Future ViV TAVI

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17641 

Submission Type:

Abstract Submission 

Authors:

Joshua Schwartz (1), Adel Alqabandi (1), Tara D'Ignazio (1), Ibrahim Alranini (1), Abdulrahman Alhalees (1), Jean Buithieu (1), Josephine Pressacco (1), Giuseppe Martucci (1), Kevin Lachapelle (1)

Institutions:

(1) McGill University, Montreal, Canada

Submitting Author:

Joshua Schwartz    -  Contact Me
McGill University

Co-Author(s):

Adel Alqabandi    -  Contact Me
McGill University
Tara D'Ignazio    -  Contact Me
McGill University
Ibrahim Alranini    -  Contact Me
McGill University
Abdulrahman Alhalees    -  Contact Me
McGill University
Jean Buithieu    -  Contact Me
McGill University
Josephine Pressacco    -  Contact Me
McGill University
Giuseppe Martucci    -  Contact Me
McGill University
Kevin Lachapelle    -  Contact Me
McGill University

Presenting Author:

Joshua Schwartz    -  Contact Me
Emory Saint Joseph's Hospital

Abstract:

Objective
Patient-prosthesis mismatch (PPM) is a limitation of surgical aortic valve replacement (SAVR), particularly in patients with a small aortic annulus. Y-incision aortic annular enlargement (AAE) permits implantation of larger surgical prostheses. We examined mid-term hemodynamics and feasibility of valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) post SAVR with AAE.

Methods
From November 2021 to February 2025, 31 consecutive patients underwent SAVR with Y-incision AAE at the Royal Victoria Hospital. Clinical and echocardiographic follow-up was 100% complete. Postoperative imaging assessed prosthetic valve hemodynamics, PPM, and suitability for future ViV TAVI.

Results
Mean age was 70 ± 7 years, 65% were female, and mean body mass index was 31 ± 9 kg/m². There was no 30-day mortality and two late non-cardiac deaths occurred (6.5%). AAE increased median left ventricular outflow tract (LVOT) diameter from 20 ± 2 to 24 ± 2 mm, with 25 of 31 patients receiving prostheses with internal diameters larger than their native LVOT. At a median follow-up of 2.6 years, median (IQR) indexed effective orifice area was 0.9 cm² (0.8–1.0), with a mean transvalvular gradient of 11 mm Hg (7–16). Using manufacturer charts intra-operatively, 61% of patients were predicted to develop PPM. Following AAE and implantation of a larger prosthesis, 7 patients (23%) had moderate PPM and 2 (6%) had severe PPM at follow-up. At baseline, 10 of 19 patients (53%) who underwent TAVI assessment had unsuitable anatomy. Following AAE, 24 of 27 patients (89%) with postoperative scans assessed had suitable anatomy for ViV TAVI. Predicted median (IQR) valve size was 29 (26–29) mm for Evolut and 26 (23–26) mm for Sapien.

Conclusion
Y-incision AAE enables implantation of larger surgical prostheses in patients with small aortic annuli, resulting in favorable mid-term hemodynamics and a lower incidence of PPM than predicted. By creating a larger surgical valve platform, AAE may facilitate implantation of an appropriately sized ViV TAVI, expanding options for lifetime management of valve disease.

Aortic Symposium:

Aortic Root

 

Keywords - Adult

Aorta - Aortic Root
Aortic Valve - Aortic Valve