Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17684
Submission Type:
Abstract Submission
Authors:
Fabian Ramirez (1), Asavari Gowda (1), Axel Gomez (1), Liang Ge (2), Joseph Leach (2), Marko Boskovski (1), Elaine Tseng (3)
Institutions:
(1) University of California San Francisco, San Francisco, CA, (2) University of California, San Francisco and San Francisco Veterans Affairs Medical Center, San Francisco, CA, (3) University of California San Francisco, South San Francisco, CA
Submitting Author:
Fabian Ramirez
-
Contact Me
University of California San Francisco
Co-Author(s):
Asavari Gowda
-
Contact Me
University of California San Francisco
Axel Gomez
-
Contact Me
University of California San Francisco
Liang Ge
-
Contact Me
University of California, San Francisco and San Francisco Veterans Affairs Medical Center
Joseph Leach
-
Contact Me
University of California, San Francisco and San Francisco Veterans Affairs Medical Center
Marko Boskovski
-
Contact Me
University of California San Francisco
*Elaine Tseng
-
Contact Me
University of California San Francisco
Presenting Author:
Fabian Ramirez
-
Contact Me
University of California San Francisco
Abstract:
OBJECTIVE
Current ascending thoracic aortic aneurysms (ATAA) repair guidelines rely primarily on maximum diameter which, like existing CT-derived measurements, largely quantifies size rather than dilation distribution along the aorta. We developed CT-derived geometric indices to characterize regional aortic morphology beyond size and evaluated their relationships with conventional measurements and clinical outcomes.
METHODS
We retrospectively studied 239 patients undergoing ECG-gated, diastolic-phase CTA surveillance for ATAA. Manual CTA segmentation yielded centerline length, total volume, and per-slice cross-sectional area (CSA). Maximum diameter and CSA-to-height ratio (CSAHR) were included for comparison. Geometric indices included Cylindrical Deviation Index (CDI, volume relative to a cylinder of mean CSA), Packing Fraction (PF, relative to maximal CSA), Focal Expansion Index (FEI, relative to median CSA), CSA coefficient of variation (CV_CSA), and Diameter Taper Ratio (DTR). Spearman correlations assessed relationships among measurements. Cox proportional hazards models adjusted for diagnosis-to-scan interval estimated hazard ratios (HR) per interquartile-range (IQR) increase for all-cause and aortic-specific mortality among patients without ATAA surgical repair.
RESULTS
Geometric indices demonstrated distinct relationships with conventional aortic size measurements. CSAHR correlated strongly with maximum diameter (rho=0.97,p<0.001), while PF (rho=-0.38), FEI (rho=0.24), and CV_CSA (rho=0.33) had weaker associations with diameter (all p<0.001). CDI was minimally associated with diameter (rho=0.12,p=0.08), suggesting characterization relatively distinct from aortic size. Among patients without surgical repair, 45 all-cause and 17 aortic-specific deaths occurred. Per IQR increase, higher CV_CSA (HR 1.48, 95% CI 1.20–1.81, p<0.001), CSAHR (HR 1.78, 95% CI 1.24–2.58, p=0.002), and diameter (HR 1.39, 95% CI 1.03–1.87, p=0.031) were associated with increased all-cause mortality. For aortic-specific mortality, higher CV_CSA was associated with increased mortality (HR 1.56, 95% CI 1.12–2.16, P=0.008), while higher FEI was associated with decreased mortality (HR 0.52, 95% CI 0.32–0.85, P=0.008).
CONCLUSIONS
Per-slice CT-derived geometric indices characterize regional ATAA morphology beyond conventional size-based measurements. Greater cross-sectional variability was associated with all-cause and aortic-specific mor