THIRD-TIME AORTIC VALVE REPLACEMENT WITH MECHANICAL HEART VALVE WITH REDO AORTIC ROOT ENLARGEMENT IN A 41 YEAR OLD FEMALE WITH A DEGENERATED SMALL BIOPROSTHESIS
Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17727
Submission Type:
Abstract Submission
Authors:
Shivani Ravichandran (1), Meeranghani Mohamed Yusuf (2), Ravi Theja Pula (3)
Institutions:
(1) Apollo hospitals, Chennai, Tamil Nadu, (2) Madras University, Chennai, Tamil Nadu, (3) Apollo hospitals, Chennai, Tamil nadu
Submitting Author:
Shivani Ravichandran
-
Contact Me
Apollo hospitals
Co-Author(s):
Meeranghani Mohamed Yusuf
-
Contact Me
Madras University
Presenting Author:
Shivani Ravichandran
-
Contact Me
Apollo hospitals
Abstract:
THIRD-TIME AORTIC VALVE REPLACEMENT WITH MECHANICAL HEART VALVE WITH REDO AORTIC ROOT ENLARGEMENT IN A 41 YEAR OLD FEMALE WITH A DEGENERATED SMALL BIOPROSTHESIS
OBJECTIVE:
To describe the surgical strategy and early outcomes of re-redo aortic valve replacement (AVR) with redo aortic root enlargement in a 41-year-old woman with a small, stenotic bioprosthetic aortic valve.
METHODS:
A 41-year-old woman underwent AVR with a mechanical valve in 2011, followed by redo AVR with a bioprosthesis and Nicks aortic root enlargement in 2019. She presented with progressive exertional dyspnoea and chest pain radiating to the left arm. Echocardiography showed severe stenosis of the 19-mm bioprosthesis, with a mean gradient of 58 mmHg and preserved left ventricular ejection fraction. Coronary angiography showed no significant disease. Re-redo AVR with redo root enlargement was planned for symptomatic bioprosthetic degeneration and a small annulus. The right femoral vessels were exposed for potential emergency peripheral cannulation. Re-redo sternotomy with extensive adhesiolysis was performed, followed by cardiopulmonary bypass using aortic and right atrial cannulation. The patient was cooled to 28°C. Del Nido cardioplegia was administered antegradely through the aortic root and subsequently through the coronary ostia after cross-clamping. The degenerated bioprosthesis was excised. Redo root enlargement was performed through the non-coronary sinus adjacent to the previous Dacron patch, with dissection extended toward the anterior mitral leaflet, similar to the Bo Yang procedure. A pericardial patch was used for reconstruction, and a 19-mm mechanical valve was implanted with pledgeted sutures. Cross-clamp and cardiopulmonary bypass times were 184 and 229 minutes, respectively.
RESULTS:
Intraoperative transoesophageal echocardiography demonstrated a well-functioning mechanical prosthesis with a mean gradient of 12 mmHg, no paravalvular leak, and preserved biventricular function. No intraoperative complications occurred.
CONCLUSION:
Re-redo AVR with redo aortic root enlargement can be successfully performed in young patients with a degenerated small bioprosthesis despite the challenges of repeat sternotomy and limited annular dimensions. Root enlargement facilitates implantation of an appropriately sized mechanical prosthesis and provides favourable immediate haemodynamics. Careful planning, meticulous adhesiolysis, and appropriate annular/root enlargement are key.
Aortic Symposium:
Aortic Root
Keywords - Adult
Adult
Aorta - Aorta
Aorta - Aortic Root
Aortic Valve - Aortic Valve
You have unsaved changes.