Early experience with total endovascular aortic arch replacement utilizing a physician-modified thoracic branch endoprosthesis

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17739 

Submission Type:

Abstract Submission 

Authors:

Kyle Miletic (1), Loay Kabbani (1), Ali Rteil (1), Hani Ghandour (1), andi peshkepija (1)

Institutions:

(1) Henry Ford Hospital, Detroit, MI

Submitting Author:

Kyle Miletic    -  Contact Me
Henry Ford Hospital

Co-Author(s):

Loay Kabbani    -  Contact Me
Henry Ford Hospital
Ali Rteil    -  Contact Me
Henry Ford Hospital
Hani Ghandour    -  Contact Me
Henry Ford Hospital
andi peshkepija    -  Contact Me
Henry Ford Hospital

Presenting Author:

Kyle Miletic    -  Contact Me
N/A

Abstract:

Objective: There are currently no FDA approved multi-branched devices for zone 0 endovascular aortic arch repair. The Gore Thoracic Branch Endoprosthesis (TBE) can be used for zone 0 arch repair but requires single vessel stenting of the innominate artery with complete cervical debranching, which carries significant morbidity. Multibranch devices avoid this but are unavailable in the United States. We report our early experience treating a second target vessel by adding a physician-modified fenestration to the Gore Thoracic Branch Endoprosthesis (TBE) plus carotid-subclavian transposition.
Methods: We reviewed 5 consecutive patients who underwent total endovascular arch repair with a physician-modified TBE at a single center between 6/2025 and 7/2026.
Centerline measurements gave the distance and clock position between the innominate artery and the left subclavian or carotid. With this, we opened the deployment sleeve on the back table and made a 1-cm slit in the graft between struts. A gooseneck snare guided a running locking 5-0 braided suture around the fenestration, and a JR4 coronary catheter was externalized through it. The device was deployed in standard fashion and the JR4 was used to catheterize the target vessel. A GORE VIABAHN VBX stent bridged the fenestration into the target artery. Technical success was defined as successful deployment with branch and fenestration patency and no type I or III endoleak on completion angiography. Follow-up CTA was obtained in all patients (figure).
Results: Median age was 72 years, 2 were male, and 4 had prior aortic surgery. Indications were aneurysm in 1 and chronic dissection in 4. The fenestration was directed to the left common carotid in 1 patient and the left subclavian in 4. Technical success was achieved in all 5. There were no operative deaths. One patient had a transient neurologic deficit that resolved fully before discharge, with no infarct on MRI. One patient had a residual type Ic endoleak at the innominate branch treated with stent extension. Over an average follow-up of 3 months, all branches and fenestrations remained patent and there were no late deaths, migrations, or new endoleaks.
Conclusions: Physician modification of TBE for zone 0 TEVAR is technically feasible and showed acceptable short- and medium-term outcomes with no major device related complications. Physician modification is adaptable to a variety of arch pathologies and may be useful in patients unsuitable for open repair.

Aortic Symposium:

Endoluminal Prostheses

Image or Table

Supporting Image: CTA.jpg

Presentation

Z0TBE.pptx
 

Keywords - Adult

Aorta - Aorta
Aorta - Aortic Arch
Aorta - Aortic Endovascular