A Novel Technique for Selective Perfusion of Multiple Ischemic Limbs in Acute Type A Aortic Dissection

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17803 

Submission Type:

Abstract Submission 

Authors:

Sasha Still (1), Blake Lyon (2), Marissa Nides (3), Ezra Y. Koh (4), Sasha Still (1)

Institutions:

(1) N/A, Birmingham, AL, (2) N/A, N/A, (3) University of Alabama, Birmingham, AL, (4) The University of Texas Health Science Center at Houston, Houston, TX

Submitting Author:

Sasha Still    -  Contact Me
N/A

Co-Author(s):

Blake Lyon    -  Contact Me
N/A
Marissa Nides    -  Contact Me
University of Alabama
Ezra Y. Koh    -  Contact Me
The University of Texas Health Science Center at Houston
Sasha Still    -  Contact Me
N/A

Presenting Author:

Sasha Still    -  Contact Me
N/A

Abstract:

Objective: To describe an aggressive, preemptive assisted perfusion strategy to minimize the risk of limb loss during surgical repair of acute type A dissection in the setting of multi-limb ischemia.

Methods: A 51-year-old African American male with complaints of severe chest pain and clinical signs of left arm and leg ischemia found to have an acute type A aortic dissection extending from the aortic root to bilateral femoral arteries with associated left external iliac artery and left axillary artery occlusions. He was taken emergently to the OR. Right radial and femoral arterial lines were places. Bilateral axillary artery chimney grafts were performed and a 5F sheath was placed into the left common femoral artery. After sternotomy, the right axillary artery graft was connected to the primary arterial line in a Y configuration and served as primary arterial inflow and cerebral perfusion line. Through a 3-way stopcock on the right axillary graft connector, two additional extension limbs were created to provide flow to the left axillary artery graft and left femoral artery 5F catheter. A total arch replacement with an FET hybrid device was performed using under circulatory arrest at 26°C. After completion of the distal anastomosis, the left common carotid and innominate artery anastomoses were performed. After separating from cardiopulmonary bypass, the left axillary graft was tunneled transpleurally into the chest and sewn to the additional sidearm of the device to restore left arm perfusion. All arterial line pressures were equal following chest closure.

Results: On POD0, the patient was extubated and neurologically intact with biphasic signal in left leg. On POD1, he developed left leg sensory deficit and repeat imaging showed focal EIA occlusion. He urgently underwent L EIA thrombectomy and stenting complicated by respiratory failure and veno-venous ECMO initiation. Ultimately, he was extubated on POD4 and decannulated from VV ECMO on POD8. Patient progressed well and discharged home on POD17. He is back at work and doing well.

Conclusions: Acute type A aortic dissection with multi-limb malperfusion is highly lethal. An aggressive strategy of upfront, assisted perfusion for multi-limb malperfusion is safe, feasible, and effective. This method avoids delay of limb perfusion during both cooling and aortic reconstruction and may ultimately impact postoperative morbidity and mortality.

Aortic Symposium:

Dissection

 

Keywords - Adult

Adult
Aorta - Aorta
Aorta - Aortic Disection
Perioperative Management/Critical Care - Perioperative Management