Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17807
Submission Type:
Abstract Submission
Authors:
Branson Taheri (1), Bo Chang Wu (2), Elizabeth Bashian (2), Gregory Fishberger (3), Meng Han Tsai (3), Rafael Malgor (4), Muhammad Aftab (5), T. Brett Reece (6)
Institutions:
(1) University of Colorado Anschutz Medical Center, Denver, CO, (2) University of Colorado Anschutz Medical Center, Aurora, CO, (3) University of Colorado, Anschutz Medical Center, Aurora, CO, Aurora, CO, (4) University of Colorado Anschutz, Denver, CO, (5) University of Colorado Anschutz Medical Center and Rocky Mountain Regional VAMC, Aurora, CO, (6) University of Colorado Hospital, Aurora, CO
Submitting Author:
Branson Taheri
-
Contact Me
University of Colorado Anschutz Medical Center
Co-Author(s):
Bo Chang Wu
-
Contact Me
University of Colorado Anschutz Medical Center
Elizabeth Bashian
-
Contact Me
University of Colorado Anschutz Medical Center
Gregory Fishberger
-
Contact Me
University of Colorado, Anschutz Medical Center, Aurora, CO
Meng-Han Tsai
-
Contact Me
University of Colorado, Anschutz Medical Center, Aurora, CO
Rafael Malgor
-
Contact Me
University of Colorado Anschutz
*Muhammad Aftab
-
Contact Me
University of Colorado Anschutz Medical Center and Rocky Mountain Regional VAMC
*T. Brett Reece
-
Contact Me
University of Colorado Hospital
Presenting Author:
Branson Taheri
-
Contact Me
University of Colorado Anschutz Medical Center
Abstract:
Objective: The advent of endovascular repair for thoracic aortic pathology has revolutionized treatment paradigms with minimally invasive strategies. However, access site complications during thoracic endovascular aortic repair (TEVAR) remains a persistent problem.
Methods: We identified all patients who underwent TEVAR by transfemoral access at a single institution from 2020 – 2025. We compared pre-operative and operative characteristics between those who had an access complication and those who did not. Variables with a trend towards a significant difference (p < 0.2) were incorporated into a scoring system to predict an access related complication that was analyzed with receiver operating characteristic analysis.
Results: Our final study cohort consisted of 262 patients who had sufficient data available for analysis. Among these, 28 patients had an access complication (10.7%). Those with an access related complication were older (mean age 67.5 vs. 61.7, p = 0.018), were less likely to be of male gender (39.3% vs. 70.1%, p = 0.002), and had higher delivery device sheath sizes (mean 22.1 french vs. 21.2 french, p = 0.015). Additionally, we included pre-operative dialysis (p = 0.126) and aneurysm procedure indication into our scoring system (p = 0.195). In this system we allocated one-point for age greater than or equal to 75, female gender, delivery device sheath size at least 22 french, aneurysm procedure indication, and pre-operative dialysis. Receiving at least two points in this system had a sensitivity of 75% and a specificity of 63%. The full receiver operating characteristic curve for this scoring system is shown in Figure 1 with an area under the curve of 0.73.
Conclusion: These data show how increasing age, increasing delivery device size, and female gender are all predictive of access related complications. We developed a scoring system to predict these issues with a moderate degree of accuracy that may be used to better counsel patients or determine when a planned, initial open femoral exposure may be indicated.
Aortic Symposium:
Endoluminal Prostheses
Keywords - Adult
Adult
Aorta - Aorta
Aorta - Aortic Endovascular
Aorta - Descending Aorta