Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17810
Submission Type:
Abstract Submission
Authors:
Branson Taheri (1), Stevenson Yip (2), Bo Chang Wu (3), Rafael Malgor (4), Muhammad Aftab (5), T. Brett Reece (6)
Institutions:
(1) University of Colorado Anschutz Medical Center, Denver, CO, (2) University of Colorado, Anschutz Medical Center, Aurora, CO, Littleton, CO, (3) University of Colorado Anschutz Medical Center, Aurora, CO, (4) University of Colorado Anschutz, Denver, CO, (5) University of Colorado Anschutz Medical Center and Rocky Mountain Regional VAMC, Aurora, CO, (6) University of Colorado Hospital, Aurora, CO
Submitting Author:
Branson Taheri
-
Contact Me
University of Colorado Anschutz Medical Center
Co-Author(s):
Stevenson Yip
-
Contact Me
University of Colorado, Anschutz Medical Center, Aurora, CO
Bo Chang Wu
-
Contact Me
University of Colorado Anschutz Medical Center
Rafael Malgor
-
Contact Me
University of Colorado Anschutz
*Muhammad Aftab
-
Contact Me
University of Colorado Anschutz Medical Center and Rocky Mountain Regional VAMC
*T. Brett Reece
-
Contact Me
University of Colorado Hospital
Presenting Author:
Branson Taheri
-
Contact Me
University of Colorado Anschutz Medical Center
Abstract:
Introduction: For blunt thoracic aortic injuries (BTAI), initial sizing for thoracic endovascular aortic repair (TEVAR) based on computed tomography (CT) may be misleading due to patient under-resuscitation on arrival. Accordingly, many surgeons advocated for intravascular ultrasound (IVUS) to be used as an adjunctive measurement technique. We hypothesized that IVUS aortic measurements may more accurately correlate to chosen TEVAR size compared to CT imaging.
Methods: We examined all patients treated with TEVAR for blunt aortic injuries at our institution from 2011-2025. We obtained pre-operative CT measurements at the site of injury, intra-operative IVUS aortic measurements as dictated in the operative note (qualitative IVUS), and intra-operative IVUS measurements as recorded in the medical record as saved imaging (recorded IVUS). We determined which measurements more accurately correlated with TEVAR size using univariate linear regression. All CT and IVUS sizes were adjusted based on an assumed 15% oversizing for TEVAR.
Results: We were able to include 32 patients in our final study cohort. Among these, 24 (75%) were male with an average age of 38.4 (std. 15.6). Patients had severe cumulative injury burdens with mean injury severity score of 29.7 (std. 10.5). The average length of coverage was 11.9cm (std. 4.2), and an average dose of 9,525 units of heparin was given intra-operatively (std. 5,655). IVUS was performed in 76% percent of cases. There were two 30-day mortalities. In linear regression analysis, CT imaging sizes had a mild predictive capacity for final TEVAR size (R2 = 0.271). Both qualitative IVUS sizes (R2 = 0.665) and recorded IVUS sizes (R2 = 0.673) showed greater predictive capacity. In the IVUS size cohort, there were only eight and seven measurements available for analysis respectively. The regression plots for CT imaging and quantitative IVUS size are shown in Figure 1.
Conclusion: Sizing for blunt thoracic aortic injury using intravascular ultrasound measurements seem to correlate more closely with final TEVAR device size used. Further studies with more frequent recording of IVUS size are needed to further assess these relationships.