Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17886
Submission Type:
Abstract Submission
Authors:
William MacDonald (1), Megan Chung (1), Yuichiro Kitada (1), Yanling Zhao (1), Yu Hohri (1), Valeria Jimenez (1), Benjamin S. van Boxtel (2), Paul Kurlansky, MD (3), Adham Elmously (1), Hiroo Takayama (1)
Institutions:
(1) NewYork- Presbyterian/Columbia University Medical Center, New York, NY, (2) Morristown Medical Center, Morristown, NJ, (3) Center for Innovation and Outcomes Research, New York Presbyterian Hospital/Columbia University, New York, NY
Submitting Author:
William MacDonald
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Co-Author(s):
Megan Chung
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Yuichiro Kitada
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Yanling Zhao
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Yu Hohri
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Valeria Jimenez
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Benjamin S. van Boxtel
-
Contact Me
Morristown Medical Center
*Paul Kurlansky, MD
-
Contact Me
Center for Innovation and Outcomes Research, New York Presbyterian Hospital/Columbia University
Adham Elmously
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
*Hiroo Takayama
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Presenting Author:
William MacDonald
-
Contact Me
NewYork- Presbyterian/Columbia University Medical Center
Abstract:
Objective: Plication of the sinotubular junction (STJ) during ascending aortic replacement may preserve or restore aortic valve (AV) function. We assessed four-year outcomes of a novel technique of patient-specific double-layer STJ plication.
Methods: From 2019 to 2025, 72 patients underwent ascending aortic repair with patient-specific STJ plication for STJ effacement due to acute type A dissection (n=40) or aneurysm (n=32), with or without associated aortic regurgitation (AR). To secure the STJ at a target diameter, a short everted Dacron graft ring is secured at the commissures with mattress sutures and plicated over a Hegar dilator to a patient-specific target diameter, based on body size and valve inspection (Fig. 1A). Primary endpoints were cumulative incidence of ≥moderate AR and AV reintervention. STJ targets were validated post hoc through guideline-derived, body surface area (BSA) indexing: STJ (cm) = 0.62*BSA+1.69.
Results: Mean preoperative STJ diameter was 37.1±5.1 mm. Mean target diameter was 27.2±0.9 mm, with stable postoperative (26.9±1.8 mm) and follow-up diameters (Fig. 1B); 61 (84.7%) target diameters were within 3 mm of BSA-predicted diameter. Preoperative AR was <moderate in 22 (68.8%) and ≥moderate in 10 (31.3%) in the aneurysm cohort, and 14 (35.0%) and 26 (65.0%) in the dissection cohort, respectively. Postoperatively, no patients had mortality, reexploration for proximal anastomotic bleeding, or ≥moderate AR before discharge. Over four years, the STJ remained stable, with 2 (2.8%) patients showing STJ diameters ≥2 mm over their targets. Four-year cumulative incidence of ≥moderate AR was 6.7% (95%CI[0.4-26.9]) for the aneurysm and 21.5% (95%CI[7.1-40.6]) for the dissection cohort (Fig. 1C) and AV reoperation occurred only in the dissection cohort: 6.1% (95%CI[1.0-18.2]). Overall, late AR was from leaflet pathology or downstream aortic complications, not STJ dilation, which was stable in all cases. Among dissection patients, 37 (92.5%) showed false lumen thrombosis on follow-up.
Conclusions: Patient-specific plication showed stable STJ diameters and no STJ-effacement-mediated AR in follow-up. Four-year rates of AR and AV reintervention are encouraging and comparable to existing supracoronary techniques. Advantages include excellent hemostasis, long-term mechanical stability, and secure reattachment of dissected layers, promoting favorable aortic remodeling. BSA-derived STJ diameters can aid a priori target selection.
Aortic Symposium:
Aortic Root
Keywords - Adult
Aorta - Aorta
Aorta - Ascending Aorta