Effect of Cusp Modification with Shaving and Decalcification on Mid-Term Outcomes Following Bicuspid Aortic Valve Repair

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17927 

Submission Type:

Abstract Submission 

Authors:

Metesh Acharya (1), Yuan Qiu (2), Navneet Kang (3), Hugo Issa (4), Aryam Toubar (3), Adam Dryden (3), Ming Hao Guo (2), Munir Boodhwani (5)

Institutions:

(1) University of Ottawa Heart Institute, Wembley, London, (2) University of Ottawa Heart Institute, Ottawa, ON, (3) University of Ottawa Heart Institute, Ottawa, NA, (4) University of Ottawa, Ottawa, ON, (5) N/A, Ottawa, ON

Submitting Author:

Metesh Acharya    -  Contact Me
University of Ottawa Heart Institute

Co-Author(s):

Yuan Qiu    -  Contact Me
University of Ottawa Heart Institute
Navneet Kang    -  Contact Me
University of Ottawa Heart Institute
Hugo Issa    -  Contact Me
University of Ottawa
Aryam Toubar    -  Contact Me
University of Ottawa Heart Institute
Adam Dryden    -  Contact Me
University of Ottawa Heart Institute
Ming Hao Guo    -  Contact Me
University of Ottawa Heart Institute
*Munir Boodhwani    -  Contact Me
N/A

Presenting Author:

Metesh Acharya    -  Contact Me
University of Ottawa Heart Institute

Abstract:

Objective:
Bicuspid aortic valve (AV) repair represents a durable alternative to AV replacement for aortic insufficiency (AI). We employ a cusp shaving and/or selective decalcification strategy to address cusp thickening and calcification, which may limit reparability. We aimed to determine the mid-term clinical and echocardiographic outcomes of cusp shaving and/or selective decalcification compared to conventional repair without this approach in patients undergoing bicuspid AV repair.
Methods:
Between October 2011 – February 2025, 151 consecutive patients underwent bicuspid AV repair at a single institution, of which 87 patients (57.6%) underwent cusp shaving and/or decalcification (S/D group) and 64 patients (42.4%) did not (non-S/D group). Pre-operative, intra-operative and post-operative data were collected prospectively and analyzed to determine mid-term survival, freedom from >2+ AI and freedom from AV re-operation.
Results:
Early post-operative outcomes were comparable between groups. 10-year survival was 96.4% in both groups (p=0.81). 10-year freedom from >2+ AI was 76.4% in the S/D group and 68.2% in the non-S/D group (p=0.97). 10-year freedom from AV re-operation was 96.4% in both groups (p=0.92).
Conclusions:
Cusp shaving and/or decalcification represents a valuable adjunctive technique to facilitate bicuspid AV repair, thereby increasing reparability in bicuspid AVs that would be otherwise be selected for replacement. Importantly, the cusp shaving and/or decalcification strategy does not compromise mid-term survival and durability.

Aortic Symposium:

Aortic Surgery Forum (Basic Aortic Research, Venue for Residents, Fellows, Junior Attendings)

 

Keywords - Adult

Aortic Valve - Aortic Valve