Transcatheter Valve-in-Valve Versus Repeat Surgical Aortic Valve Replacement for Failed Bioprosthetic Valves: A Systematic Review and Meta-Analysis of Early Clinical and Hemodynamic Outcomes

Presented During:

Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square  
Posted Room Name: Exhibit Hall & Metropolitan Ballroom  

Abstract No:

17940 

Submission Type:

Abstract Submission 

Authors:

Sameh Said (1), Ahmed Wahba (2), Ahmad Omar Saleh (3), Osama Elbahy (4), Ahmed Harfoush (5), Ahmed Hageen Hageen (5)

Institutions:

(1) Westchester Medical Center, Valhalla, NY, (2) Faculty of Medicine, Port Said University, Port Said, Egypt, Damietta, Egypt, (3) Faculty of medicine, the University of Jordan, Amman, NA, (4) N/A, Port Said, Egypt, (5) N/A, N/A

Submitting Author:

Sameh Said    -  Contact Me
Westchester Medical Center

Co-Author(s):

Ahmed Wahba    -  Contact Me
Faculty of Medicine, Port Said University, Port Said, Egypt
Ahmad Omar Saleh    -  Contact Me
Faculty of medicine, the University of Jordan
Osama Elbahy    -  Contact Me
N/A
Ahmed Harfoush    -  Contact Me
N/A
Ahmed Hageen Hageen    -  Contact Me
N/A

Presenting Author:

Sameh Said    -  Contact Me
Westchester Medical Center

Abstract:

Objective: With expanding use of bioprosthetic aortic valves, structural valve deterioration requiring reintervention is increasingly common. Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) and redo surgical aortic valve replacement (redo-SAVR) represent the two main treatment strategies. This meta-analysis aims to compare early clinical, safety, and hemodynamic outcomes between ViV-TAVR and redo-SAVR.
Methods: A comprehensive literature search was performed across PubMed, Web of Science, Cochrane Library, and Scopus through May 30, 2026. Nineteen comparative studies including 20,221 adults with failed surgical aortic bioprostheses (10,637 undergoing ViV-TAVR; 9,584 undergoing redo-SAVR) met inclusion criteria. Pooled risk ratios (RR) and mean differences (MD) with 95% confidence intervals (CI) were calculated using random-effects models.
Results: Compared to redo-SAVR, ViV-TAVR was associated with significantly lower early all-cause mortality (RR 0.54; 95% CI, 0.44–0.65), reduced rates of acute kidney injury (RR 0.56; 0.33–0.94), major or life-threatening bleeding (RR 0.48; 0.35–0.67), new-onset atrial fibrillation (RR 0.27; 0.17–0.43), and reoperation for bleeding (RR 0.13; 0.06–0.27), as well as shorter hospital (MD −4.28 days) and ICU stays (MD −2.22 days). However, mean transvalvular gradients were higher after ViV-TAVR (MD 3.65 mmHg). Rates of stroke, pacemaker implantation, high-degree atrioventricular block, myocardial infarction, paravalvular leak, reintervention, readmission, and endocarditis were similar between groups.
Conclusions: ViV-TAVR offers a less invasive alternative with favorable early procedural safety, but redo-SAVR provides superior valve hemodynamics characterized by lower residual gradients. By removing the degenerated prosthesis, surgery restores effective orifice area and avoids the inherent flow limitations of the valve-in-valve approach-advantages that are particularly important for younger patients, individuals with small aortic annuli, or those with longer life expectancies. Redo-SAVR remains a durable and definitive treatment and should serve as the benchmark against which less invasive strategies are compared.

Aortic Symposium:

Aortic Root

Presentation

ValveinValve.pptx
 

Keywords - Adult

Adult
Aorta - Aorta
Aortic Valve - Aortic Valve