Introducing a Simplified Supported Ross: The Spokane Scaffold
Presented During:
Thursday, November 19, 2026: 6:03AM - Friday, November 20, 2026: 6:03PM
Sheraton Times Square
Posted Room Name:
Exhibit Hall & Metropolitan Ballroom
Abstract No:
17942
Submission Type:
Abstract Submission
Authors:
William Sham (1), Travis Hull (2), Fenton McCarthy (2), Erik Condon (2), Matthew Forrester (2)
Institutions:
(1) Providence Sacred Heart Medical Center, Seattle, WA, (2) Providence Sacred Heart Medical Center, Spokane, WA
Submitting Author:
William Sham
-
Contact Me
Providence Sacred Heart Medical Center
Co-Author(s):
Travis Hull
-
Contact Me
Providence Sacred Heart Medical Center
Fenton McCarthy
-
Contact Me
Providence Sacred Heart Medical Center
Erik Condon
-
Contact Me
Providence Sacred Heart Medical Center
Matthew Forrester
-
Contact Me
Providence Sacred Heart Medical Center
Presenting Author:
William Sham
-
Contact Me
Providence Sacred Heart Medical Center
Abstract:
Objective: Fully supporting the Ross autograft adds technical complexity and confines its natural motion but reinforcing only the aortic annulus and/or sinotubular junction leaves the sinuses vulnerable to late dilatation and subsequent aortic insufficiency. We describe a simple method that minimizes dilatation of the entire autograft without compromising its innate dynamicity.
Methods: Nine patients underwent the Ross procedure supported by the Spokane Scaffold from 2025-2026. Preoperative factors and postoperative echocardiographic outcomes were reviewed retrospectively. Valsalva grafts 3-4 mm larger than the native aortic annulus were selected to construct the scaffold. The proximal and distal portions of the graft were trimmed, leaving 3 mm and 5 mm of material, respectively. Three rectangular apertures 3 mm taller than the geometric leaflet height were excised from the graft to leave room for coronary reimplantation and for the sinuses to expand and contract, and a 2-3 mm wide vertical strip of material in between the apertures were retained and aligned with the commissures. The autograft commissures were resuspended such that the suspension height spanned 3 mm of space below the annulus plus the geometric leaflet height plus 3 mm above each commissural post.
Results: All nine patients were male and had bicuspid aortic valves. Median age was 50 (range: 27-56). Four (44.4%) patients presented with predominant aortic stenosis (AS), three (33.3%) with predominant AI, and two (22.2%) with mixed AS-AI. Two (22.2%) presented with aortic root aneurysm. Median native aortic annulus diameter was 27 mm (range: 26-31). Four (44.4%) underwent concomitant ascending aorta replacement. Eight (88.9%) had no or trace native pulmonary insufficiency (PI); one (11.1%) had mild PI. The median bypass and cross-clamp times were 183 (range: 147-233) and 161 minutes (range: 131-196) respectively. Median length of ICU stay was two days. Median length of hospital stay was five days. Median time since surgery is 6 months (range: 3-16). Zero deaths or reinterventions have occurred. All patients had no or trace AI immediately after the operation. At one month, five (71.4%) had no or trace AI, two (28.9%) had mild AI, and zero had > mild AI.
Conclusions: This new technique eliminated ≥ mild autograft AI immediately after the operation in all patients with promising early outcomes, demonstrating its potential to support the entire autograft and preserve its natural geometry.
Aortic Symposium:
Aortic Root
Keywords - Adult
Aorta - Aorta
Aorta - Aortic Root
Aortic Valve - Aortic Valve
Pulmonary Valve - Pulmonary Valve