Simplified Frozen Elephant Trunk Technique (SD-FET): How We Do It Now (Technical Considerations and Current Practice)

Amin SERRADJ Poster Presenter
University of Paris XII
meaux
France
 - Contact Me

Amin SERRADJ is a French Cardiac Surgeon at Henri Mondor University Hospital -APHP in creteil,working in cardiovascular surgery with a focus on valvular, aortic and advanced heart failure procedures. Trained in Oran (Algeria)  and Paris (Sorbonne and Paris-Descartes), he holds multiple diplomas in cardiothoracic and congenital Cardiac surgery, valvular surgery and mechanical circulatory support,completed by an internship at Mayo Clinic Hospital (Rochester - USA) . An active member of french thoracic and cardiovascular surgical society , he contributes to educational initiatives and international collaborations around modern Cardiac surgery.    

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Background: The Frozen Elephant Trunk (FET) technique has become a cornerstone in the management of complex aortic arch diseases. However, prolonged circulatory arrest remains a major concern because of its association with neurological and visceral complications. A short-distal Frozen Elephant Trunk (SD-FET) strategy using a 100-mm Thoraflex™ Hybrid prosthesis has recently been proposed to simplify distal anastomosis and reduce circulatory arrest time while maintaining favorable early outcomes. We report our initial experience with this technique in a dedicated aortic center.

Methods: A retrospective observational study was conducted including all consecutive patients undergoing SD-FET with a 100-mm Thoraflex™ Hybrid prosthesis between May 2025 and June 2026 at a single high-volume aortic center. Baseline characteristics, operative variables, and early postoperative outcomes were analyzed.

Results: Eighteen patients underwent SD-FET during the study period. Median age was 65 years, and 88% were male. Surgical indications included acute aortic dissection in 38.9% (n = 7), chronic aortic dissection in 33.3% (n = 6), and aortic arch aneurysm in 27.8% (n = 5). Median cardiopulmonary bypass time was 253 minutes, aortic cross-clamp time 110 minutes, and circulatory arrest time 8.3 minutes, with a mean lowest body temperature of 32.8°C.Thirty-day (in-hospital) mortality was 5.6% (n = 1), occurring in a patient operated on for acute aortic dissection. No postoperative stroke or spinal cord injury was observed.

Conclusions:Our experience with SD-FET suggests that the short-distal Frozen Elephant Trunk strategy using a 100-mm Thoraflex™ Hybrid prosthesis is a safe and reproducible approach for complex aortic arch surgery. The technique was associated with an exceptionally short circulatory arrest time while achieving excellent early neurological outcomes, with no stroke or spinal cord injury. Larger studies with longer follow-up are warranted to evaluate the impact of this strategy on aortic remodeling and long-term clinical outcomes.

Authors
Amin SERRADJ (1), eric bergoend (2), COSTIN RADU (3), Thierry Folliguet (4)
Institutions
(1) University of Paris XII, meaux, France, (2) N/A, N/A, (3) N/A, PARIS, France, (4) Cardiac surgery, CHU Mondor, Créteil, France, Creteil, France

Aortic Symposium

Aortic Arch