Dynamic Behavior of the Aortic Root and Aortic Annulus in Severe Aortic Stenosis: A Four-Dimensional Multiphase Computed Tomography Analysis

Amine Fikani Poster Presenter
Limoges
France
 - Contact Me

I trained in cardiac surgery at Hotel-Dieu de France (Lebanon) and at Hospice Civil de Lyon and Limoges University Hospital (France). I am a member of the french society of cardiothoracic surgery. I recently obtained a masters of science for my work on the aortic valve.

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Objective: Transcatheter aortic valve replacement (TAVR) sizing relies on annular measurements obtained in a single cardiac phase. We assessed the dynamic three-dimensional (3D) behavior of the aortic root and annulus in severe aortic stenosis and its relationship with calcium burden.

Methods: Fifty-four consecutive patients undergoing pre-TAVR multiphase cardiac computed tomography for severe native aortic stenosis were reviewed retrospectively; valve-in-valve procedures and predominant regurgitation were excluded. Ten phases were reconstructed across the RR interval. Using previously described in-house software, the anatomical aortic annulus (AA) (the 3D line of leaflet insertion) was reconstructed at each phase from 18 points on 9 orthogonal planes rotating around the annular axis, interpolated by cubic spline. Planes were also created at the virtual basal ring (VBR), the Valsalva sinuses and the sinotubular junction (STJ). Area, perimeter and eccentricity index were computed per phase; distensibility was the relative change between maximal and minimal dimensions. Patients were divided into tertiles of valve calcium score and distensibility compared by one-way ANOVA.

Results: Mean calcium score was 3043 +/- 1301 and 40 of 54 patients (74.1%) had a tricuspid valve. A sequential expansion pattern was observed, beginning at the VBR, followed by the true annulus, the Valsalva sinuses and finally the STJ; the same sequence was seen for area and perimeter.

Distensibility of area was 21.5 +/- 9.7% at the VBR and 14.7 +/- 5.8% at the AA; distensibility of perimeter was 11.7 +/- 5.7% and 12.3 +/- 4.9%, respectively. Distensibility did not differ across calcium score tertiles, for area (VBR 18.6 vs 21.5 vs 24.3%, p=0.36; AA 13.8 vs 17.0 vs 13.1%, p=0.21) or perimeter.

The eccentricity index changed significantly between systole and diastole at the VBR (0.57 +/- 0.11 vs 0.64 +/- 0.10, p<0.005) and the AA (0.44 +/- 0.10 vs 0.48 +/- 0.10, p<0.005), with no change at the Valsalva sinuses (p=0.47) or STJ (p=0.94).

Conclusions: In severe aortic stenosis the aortic root remains dynamic. The sequence of root expansion, annular distensibility and cyclic change in annular shape are preserved and independent of calcium burden, suggesting that calcific disease does not cause generalized annular stiffening. Single-phase sizing may underrepresent the anatomy at deployment, and dynamic assessment merits evaluation for refining prosthesis selection.

Authors
Amine Fikani (1), Elie Mousseaux (2), Damian Craiem (3), Victor Jebara (4), tarek smayra (5), tarek tannir (5), Jerome Jouan (6), francesca pitocco (7)
Institutions
(1) N/A, Limoges, France, (2) Department of Radiology, Georges Pompidou European Hospital, Paris, NA, (3) Favaloro University, Instituto de Medicina Traslacional, Trasplante y BioingenierĂ­a, CONICET, Buenos Aires, NA, (4) N/A, Beirut, (5) hotel-dieu de france, Beirut, Lebanon, (6) Dupuytren Limoges University Hospital, Limoges, France, (7) HEGP, paris, France

Aortic Symposium

Aortic Root