Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square
Room: Exhibit Hall & Metropolitan Ballroom
Objective: Complex obstruction of the descending thoracic aorta is rare and technically challenging; its collateral intercostal network places the spinal cord at ischemic risk. Conventional cross-clamp resection with left heart bypass and endovascular repair both require favorable anatomy. We describe an off-pump extra-anatomic bypass through a left thoracotomy under partial side-biting clamps, without left heart bypass, in two patients in whom both were precluded.
Methods: Both underwent left posterolateral thoracotomy with single-lung ventilation and cerebrospinal fluid drainage. A 20-mm Dacron graft was anastomosed end-to-side proximal and distal to the lesion. The native aorta was neither cross-clamped nor mobilized, preserving antegrade collateral perfusion and avoiding intercostal reimplantation. Neither required cardiopulmonary bypass, sternotomy, or laparotomy. Patient 1, aged 69, had calcific stenosis with a 7-mm lumen, claudication, and hypertension on five agents; the fifth and ninth interspaces allowed a two-segment bypass from the arch to the supradiaphragmatic aorta. Patient 2, aged 59, had congenital coarctation and a 3.8-cm vascular paraspinal mass, resected and removed with clip ligation of its feeders before a single-segment bypass through the fifth interspace.
Results: Both recovered with intact neurologic function and no spinal cord ischemia; follow-up computed tomography showed widely patent grafts. In Patient 1, femoral systolic pressure was half the radial value before bypass and equalized after reperfusion; extubated on day 1, her course included ileus, respiratory insufficiency, and a perigraft hematoma, managed conservatively. She was discharged on day 13 with restored pedal pulses; at one month blood pressure was 118/65 mmHg with markedly improved ambulation. Patient 2 was extubated in the operating room, recovered uneventfully, was discharged on day 5, with only one antihypertensive and is ambulating well.
Conclusions: Off-pump extra-anatomic bypass through a left thoracotomy using partial side-biting clamps is feasible for complex descending thoracic aortic obstruction unsuitable for conventional repair. It adapts to long-segment calcific disease and to focal coarctation with concurrent intrathoracic procedures. Avoiding sternotomy, laparotomy, cross-clamping, and both cardiopulmonary and left heart bypass while preserving antegrade perfusion reduces risk of spinal cord ischemic even when collaterals are deliberately ligated
Authors
Abhishek Chakraborty (1), Kevin Hayes (1), Berk Inan (1), Russell Pepe (1), Hirohisa Ikegami (1), Farooq Mirza (1), Anthony Lemaire (1), Mark Russo (1), Leonard Lee (1)
Institutions
(1) Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ
Aortic Symposium
Descending/Thoracoabdominal Aorta