Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square
Room: Exhibit Hall & Metropolitan Ballroom
Objective: There is increasing focus on the appropriate surgical aortic valve option,especially for younger patients.Resilia bovine pericardial tissue technology reduces calcification and pannus formation. To date,peer-reviewed data from the COMMENCE trial extend to 7 years of follow-up.RES-ITA (RESilia aortic tissue valve ITAlian) Registry is a multicenter observational Italian registry aimed at evaluating the mid-term clinical outcomes and hemodynamic performance of the Resilia tissue bovine aortic valve bioprosthesis. Methods: From October 2017 to January 2024,275 consecutive patients underwent isolated or combined aortic valve replacement with the new aortic bioprosthesis incorporating Resilia tissue. Patients aged <18 years, pregnant women, and patients undergoing LVAD implantation were excluded. Time-to-event outcomes were estimated using Kaplan-Meier analysis. Structural valve deterioration (SVD) and Bioprosthetic Valve Failure (BVF) were assessed according to VARC-3 criteria. Results: Mean age was 60.5 years (range, 24-83 years), 202 patients (73.4%) were male, and 124 (45.1%) had a bicuspid aortic valve.Combined procedures were performed in 129 (46.9%) patients. Previous cardiac surgery was reported in 21 patients (7.6%),while 6.5% underwent urgent or emergent surgery.The median follow-up was 58 months (IQR, 36–78 months). At 7 years, overall survival was 91.4 ±2.1% and freedom from valve-related death was 98.8±0.7%.Freedom from aortic regurgitation ≥3+ and from infective endocarditis was 96.2±1.4% and 92.8±1.9%,respectively.Freedom from aortic prosthetic reoperation and from BVF was 93.7±1.7% and 92.3±1.9%, respectively.Infective endocarditis accounted for 13 of 16 BVF cases.At 7 years, freedom from thromboembolism, from haemorrhage and from SVD was 97.0±2.0%, 99.2±0.6% and 97.1±1.3%,respectively. At a median echocardiographic follow-up of 36 months,the mean within-patient change in transprosthetic gradient was +1.58 mmHg (95% CI,0.65-2.52), indicating stable hemodynamic performance. Conclusions: This is the first Italian multicenter registry evaluating the clinical and hemodynamic performance of the new aortic bioprosthesis incorporating Resilia tissue. At 7-year follow-up, this novel bioprosthesis demonstrated a favorable safety profile, good durability, and stable hemodynamic performance. Infective endocarditis, rather than SVD, emerged as the predominant contributor to BVF and reoperation. Longer-term follow-up is needed.
Authors
Ilaria Chirichilli (1), Jacopo Alfonsi (2), diego cugola (3), Margherita Dalla Tomba (4), Marco Di Eusanio (2), Augusto D'Onofrio (5), brenno fiorani (6), Federica Gramegna (7), Andrea Lechiancole (8), Maurizio Merlo (3), Paolo Nardi (5), Lucia Torracca (7), Erika Troncone (6), Igor Vendramin (9), Emmanuel Villa (4), Giampaolo Luzi (1)
Institutions
(1) San Camillo Forlanini Hospital, Rome, Italy, (2) Lancisi Cardiovascular Center - Polytechnic University of Marche, Ancona, Italy, (3) ASST Papa Giovanni XXIII, Bergamo, Italy, (4) Poliambulanza Foundation Hospital, Brescia, Italy, (5) Tor Vergata University Hospital, Rome, Italy, (6) San Giuseppe Moscati Hospital, Avellino, Italy, (7) IRCCS Humanitas Research Hospital, Rozzano, Milano, Italy, (8) University Hospital of Udine, Udine, Italy, (9) University Hospital of Udine, Udine, italy
Aortic Symposium
Natural History/Follow-Up