Zone 0 TEVAR for Acute Type A Aortic Dissection in Prohibitive-Risk Patients: Early Experience Including Combined VA-ECMO and Microaxial Flow Pump Support

Salim Aziz Poster Presenter
George Washington University Hospital
Washington, DC 
United States
 - Contact Me

Salim Aziz, MD, FACS

Salim Aziz, MD, FACS, is Clinical Professor of Cardiovascular Surgery at The George Washington University, with expertise in high-risk pulmonary embolism, ECMO and hybrid extracorporeal circuits, adult cardiac surgery—including aortic surgery, endocarditis, and coronary surgery—and combined cardiac and peripheral vascular surgery. He is also active in cardiovascular innovation.

Dr. Aziz graduated from St. Mary’s Hospital Medical School in London and began transplant training at the University of Cambridge under Professor R. Y. Calne. He subsequently joined Drs. Bruce Reitz and Norman Shumway at Stanford University as a Research Fellow, participating in pioneering studies establishing the feasibility of heart and heart-lung transplantation with cyclosporine immunosuppression. He completed surgical training at Stanford, followed by a cardiovascular surgery fellowship at the University of Minnesota and advanced training in pulmonary hypertension surgery at UC San Diego.

He later joined the faculty at the University of Washington, rising to Associate Professor, where he co-managed the heart transplantation program and conducted research on transplant coronary vasculopathy. He was an early adopter of multidetector CT technology for detecting coronary artery disease and incorporating coronary imaging into surgical decision-making.

His current interests include ECMO and mechanical circulatory support, high-risk pulmonary embolism, advanced heart failure, complex aortic surgery, donation after circulatory death, cardiac xenotransplantation, and emerging therapies for heart failure with preserved ejection fraction.

For nine years, Dr. Aziz served on the U.S. FDA Circulatory System Devices Advisory Panel, providing expertise in cardiovascular devices and emerging technologies. He remains engaged in complex cardiovascular care, research, education, mentorship, and development of novel therapies for patients with advanced cardiovascular disease.

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Objective: Open repair remains the standard treatment for acute type A aortic dissection (ATAAD), but a subset of patients presents with prohibitive operative risk. We report early experience with Zone 0 thoracic endovascular aortic repair (TEVAR) for proximal aortic pathology in two patients deemed unsuitable for conventional surgery.
Methods: Retrospective review of 2 consecutive patients undergoing Zone 0 TEVAR for ATAAD after multidisciplinary review deemed open repair prohibitive. Patient 1, a 53-year-old man, presented with non-ST-elevation myocardial infarction and cardiogenic shock. Angiography demonstrated critical left main disease, treated with left main-circumflex stenting and a transvalvular microaxial flow pump. He developed biventricular failure, metabolic acidosis (lactate 12.7 mmol/L), shock liver, acute kidney injury, and escalating vasopressor requirements, requiring peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO). Transesophageal echocardiography and computed tomography angiography (CTA) identified ATAAD extending to the innominate origin with severe true lumen compression. Patient 2, a 69-year-old man, was found unresponsive with severe hypertension; head computed tomography demonstrated a 3.3-cm cerebellar hemorrhage and CTA revealed dissection confined to the ascending aorta.
Results: Both patients underwent successful Zone 0 TEVAR with exclusion of the proximal entry tear, preservation of the coronary ostia, and no open repair. In Patient 1, combined VA-ECMO and microaxial pump support (upgraded to a higher-output device via the left axillary artery) maintained hemodynamic stability and facilitated true lumen expansion before definitive repair; he demonstrated initial neurologic recovery but sustained a fatal intracerebral hemorrhage on postoperative day 12. Patient 2 underwent decompressive neurosurgery with neurologic improvement, followed by uneventful Zone 0 TEVAR, and is alive with satisfactory recovery at 37 days. There were no device-related complications, retrograde dissections, or strokes attributable to the repair.
Conclusions: Zone 0 TEVAR is technically feasible for proximal aortic pathology in selected prohibitive-risk patients and may provide an alternative when conventional surgery is not feasible, including profound cardiogenic shock requiring combined VA-ECMO and microaxial pump support. Further study is needed to define selection criteria and long-term outcomes.

Authors
Salim Aziz (1), Jonathan Reiner (1), Christian Nagy (1), Jenna Aziz (2), Shawn Sarin (1)
Institutions
(1) George Washington University Hospital, Washington, DC, (2) Ohio State University Medical Center, Columbus, OH

Aortic Symposium

Dissection