Impact of Aortic Root Reconstruction Strategy On Anatomical Suitability For Future Valve-in-Valve TAVR

Egor Petrochenkov Poster Presenter
Maimonides Medical Center
Brooklyn, NY 
United States
 - Contact Me

MEDICAL SCHOOL 

The First Moscow State Medical University named by I.M. Sechenov, M 

INTERNSHIP 

University of Illinois at Chicago, Chicago, IL  Department of Surgery 

General Surgery Residency (2023-2024) 

RESIDENCY 

Maimonides Medical Center, Brooklyn, NY Department of Surgery 

General Surgery Residency (2024-present) 
 

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Background
Lifetime management for patients undergoing aortic root replacement with a bioprosthetic valve must consider future prosthetic valve degeneration (PSD) and the need for redo surgery or valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) in the root. However, comparative data evaluating the feasibility of ViV-TAVR in different bioprosthetic aortic root reconstruction techniques is limited.
Aims
Evaluation of anatomical suitability for future ViV-TAVR in a Modified Offset Bio-Bentall compared to a Classic Bio-Bentall procedure.
Methods
Between 2012 and 2025, 154 patients underwent a root replacement procedure. In 82 patients, a postoperative computed tomography angiography was available (Modified Offset Bio-Bentall n=54; Bio-Bentall n=28) to evaluate the feasibility of a ViV-TAVR-in-root implantation. Criteria for suitability for ViV-TAVR are right and left coronary heights more than ≥10 mm and virtual valve-to-coronary (VTC) distance ≥4 mm. Patients were stratified according to root reconstruction technique, and anatomical suitability for future ViV-TAVR was compared between groups.
Results
Eighty-two patients underwent postoperative CT analysis following bioprosthetic root replacement (Modified Offset Bio-Bentall, n=54; Bio-Bentall, n=28). Patients undergoing Modified Offset Bio-Bentall had a higher BSA (2.03±0.23 vs 1.91±0.23 m²; p=0.03). A VTC ≥4 mm was more frequently achieved after Bio-Bentall compared with Modified Offset Bio-Bentall (82.1% vs 35.2%; p<0.001). Mean VTC was also greater after Bio-Bentall for both the left (5.1±2.0 vs 3.7±2.0 mm; p=0.02) and right coronary arteries (5.6±2.1 vs 4.2±1.9 mm; p<0.001). Both coronary heights were >10 mm in most patients (96.4% vs 92.6%; p=0.49). Overall predicted eligibility for ViV-TAVR was significantly higher after Bio-Bentall (82.1% vs 29.6%; p<0.001). Bio-Bentall was associated with larger aortic grafts (30.3±1.78 vs 29.3±1.99 mm; p=0.01) and a greater graft-to-valve size difference (5.21±2.13 vs 2.03±1.54 mm; p<0.001). Conversely, Modified Offset Bio-Bentall was associated with implantation of larger surgical valves (27.3±1.6 vs 25.1±2.0 mm; p<0.001), including among patients predicted to be eligible for ViV-TAVR (27.3±1.78 vs 24.9±2.04 mm; p=0.01).
Conclusions
The best approach to lifetime management of aortic root replacement when a bioprosthetic valve is being implanted is not clear. Offset technique will allow for a larger valve to be implanted.