Background: A hybrid graft (HG), with open and endograft components, is an important option for complex aortic arch disease. We compared perioperative outcomes for this operation in acute versus non-acute settings.
Methods: We retrospectively reviewed 60 consecutive patients who had HG insertion from July 2022 to June 2026 in a single healthcare system. Patients were classified into acute (repair ≤14 days from presentation) and non-acute (repair >14 days from presentation) conditions. Subsequent thoracic endovascular aortic repair (TEVAR) was evaluated as a secondary procedural outcome. Major adverse events were defined as postoperative mortality (in hospital or within 30 days), stroke, spinal cord ischemia, thromboembolic event, recurrent laryngeal nerve injury, bleeding requiring reoperation, and new hemodialysis requirement. Continuous and categorical variables were compared using Mann-Whitney U and Fisher's exact tests, respectively.
Results: Of the 60 patients studied, 19 (32%) were classified as acute and 41 (68%) as non-acute. Early mortality was similar between groups (1/19 [5%] vs. 3/41 [7%], P=1.000). Major adverse events occurred in 23/60 (38%) patients overall, higher in the acute group versus the non-acute group (10/19 [53%] vs. 13/41 [32%], P=0.157), but statistically insignificant. Stroke was also more frequent in the acute group (5/19 [26%] vs. 3/41 [7%], P=0.095), but insignificantly. New postoperative hemodialysis was required more frequently in the acute group (5/19 [26%] vs. 1/41 [2%], P=0.010). HG insertion in the acute setting was associated with shorter cardiopulmonary bypass times (143 vs. 190 minutes, P=0.023) and more frequent use of the shorter 10-cm endograft component (13/19 [68%] vs. 15/41 [37%], P=0.028). Subsequent TEVAR was done in 17/60 (28%) patients overall: 3/19 (16%) in acute patients and 14/41 (34%) in non-acute patients (P=0.219) with a median time to TEVAR of 2 days for acute and 44 days non-acute conditions.
Conclusions: HG insertion for aortic arch disease was associated with major adverse events in half the patients in the acute setting and a third of patients in the non-acute setting, with an overall mortality of 7%. Though postoperative mortality is relatively low after HG insertion, morbidity is considerable, especially in the acute setting.
Authors
William DeVries (1), Glen Smith (2), Ethan Pavlovsky (3), Hani Annabi (2), Gerilyn Boyle (4), Brower Strong (5), J. Michael DiMaio (6), William Brinkman (7), Charles Roberts (2)
Institutions
(1) Baylor Scott & White Research Institute, Plano, TX, (2) Baylor University Medical Center, Dallas, TX, (3) Baylor Scott & White Research Institute, The Colony, TX, (4) Baylor University Medical Center, Dallas , TX, (5) Baylor Scott & White Research Institute, Dallas, TX, (6) Baylor Scott & White Health, Dallas, TX, (7) Baylor Scott & White Health, Plano, TX