Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square
Room: Exhibit Hall & Metropolitan Ballroom
Objective: Total hospitalization cost in complex aortic surgery reflects multiple factors across the episode of care. With expanding hybrid and endovascular options, efficient resource utilization is paramount. We compared a commercially available integrated hybrid frozen elephant trunk (FET) prosthesis with a component-based strategy using separate surgical and endovascular grafts, evaluating hospitalization cost, operative efficiency, and clinical outcomes.
Methods: Single-center retrospective review of 97 FET procedures performed from 2023–2025 (83 component-based, 14 hybrid). Costs were standardized to 2025 U.S. dollars. Mean cost differences and 95% CI were estimated from 10,000 bootstrap resamples stratified by treatment. Adjusted total hospital costs were estimated with a gamma generalized linear model (log link), accounting for prespecified case-mix factors, with marginal standardization.
Results: Index FET was emergent/salvage in 0% hybrid vs 36.1% component cases (0/14 vs 30/83, P=.004), and preoperative malperfusion was present in 0% vs 26.5% (0/14 vs 22/83, P=.035). Mean implant cost was $43.2K vs $29.7K (difference, +$13.4K; CI, $7.9K-$19.4K), while nonimplant supply cost was similar (difference, +$0.9K; CI, -$0.6K to $2.3K). Mean unadjusted total hospital cost was $227.6K vs $189.9K (difference, +$37.7K; CI, -$12.5K to $93.8K). Adjusted mean total cost was $236.8K vs $188.6K (difference, +$48.1K; CI, -$2.0K to $113.1K; cost ratio, 1.26; CI, 0.99-1.62). Cardiopulmonary bypass (228.2±63.9 vs 243.8±73.9 min, P=.446) and cross-clamp times (156.5±62.8 vs 156.7±65.1 min, P=.990) were similar. Body ischemia (50.6±14.2 vs 69.4±19.0 min, P<.001) and cerebral ischemia times (12.4±11.3 vs 20.6±13.7 min, P=.033) were shorter with hybrid FET. New postoperative stroke occurred in 14.3% vs 15.7% (2/14 vs 13/83, P=1.000), new postoperative spinal cord injury in 0% vs 2.4% (0/14 vs 2/83, P=1.000), 30-day mortality in 0% vs 12.0% (0/14 vs 10/83, P=.349), and 1-year mortality in 21.4% vs 24.1% (3/14 vs 20/83, P=1.000).
Conclusions: Component-based FET patients presented with greater preoperative acuity. Still, hybrid FET had higher implant acquisition costs and a numerically higher adjusted hospitalization cost (+$48.1K), but shorter body and cerebral ischemia times without significant differences in major postoperative complications or mortality. These findings highlight a potential tradeoff between economic cost and operative efficiency.
Authors
Oscar Holmvard (1), Eric Jeng (2), Tyler Loftus (1), Alexandra Murillo Solera (1), Alexander Makkinejad (1), Edward Churuba (1), Eric Pruitt (3), John Spratt (4), Philip Hess (1), Kirsten Freeman (5), Eddie Manning (6), Tomas Martin (7), Thomas Beaver (8)
Institutions
(1) University of Florida, Gainesville, FL, (2) University of Florida- Shands, Gainesville, FL, (3) University of Florida Health, Gainesville, FL, (4) University of Florida Shands Hospital, Gainesville, FL, (5) Shands UF Health, Gainesville, FL, (6) UF Health, Gainesville, FL, (7) Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, (8) UF Health Shands Hospital, Gainesville, FL
Aortic Symposium
Aortic Arch