Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square
Room: Exhibit Hall & Metropolitan Ballroom
Objective: Valve durability is shaped by recognized factors, but endpoint definition is an overlooked one that may shift estimates as much (Fig. 1A). We assessed methods of defining echocardiography-based endpoints of late aortic regurgitation (AR) in Marfan patients after aortic root replacement (ARR). Methods: Systematic review identified 238 publications (1992-2026) reporting echocardiographic AR outcomes after aortic valve-sparing (AVS) and valve-replacing (AVR) ARR. AR reporting methods included time‑to‑event analysis (n=138, 58%), last‑follow‑up AR grade (n=70; 29%), and longitudinal methods (n=19; 8%). Among these studies, AR endpoints were defined inconsistently; the same descriptive AR grade was often reported under different numerical thresholds. We designed AR endpoints from 3 categories: AR threshold, pattern of occurrence, and association with reintervention. Five AR endpoints were tested: any new, recurrent, persistent, progressive AR ≥2+, and any new AR ≥3+. Each endpoint was evaluated using all available assessments and, separately, only Imaging Core–adjudicated ones. Specification curve analysis tested the robustness of the AVS-versus-AVR hazard ratio (HR) across specifications. Combined with adjustment for repair volume and patient subsets, these yielded 160 specifications. Multistate models evaluated AR as a fluctuant status over time, with reintervention and death as competing events. Analyses used the Aortic Valve Operative Outcomes in Marfan Patients (AVOMP) registry from 316 patients who underwent AVS (n=239) or AVR (n=77). Results: Across 160 specifications, AVS was associated with higher risk of AR than AVR in all models (HR >1). However, 70 specifications (44%) were statistically significant favoring AVR on risk of AR. Endpoint definition was the most important factor for statistical significance of higher AR risk in AVS. Definitions requiring persistent or progressive AR were less likely to show significant differences between groups (Fig. 1B). The multistate model showed that AVS patients not only transitioned to AR ≥2+ more frequently than AVR patients (HR 13.0) but also returned to AR <2+ at a lower rate (HR 0.6). As a result, AVS patients accumulated more time with AR ≥2+ over 10 years (0.81 vs 0.02 y). Conclusions: The endpoint definitions used to evaluate valve durability are a critical factor in the reporting of long-term outcomes of AVS in Marfan patients. Their variability limits the generalizability of results.
Authors
Ivan Murrieta-Alvarez (1), D. Craig Miller (2), Heidi Connolly (3), Camilo A. Vargas-Dutrenit (1), Ginger Etheridge (1), Susan Green (1), Scott LeMaire (4), Thoralf Sundt (5), Leonard Girardi (6), Puja Kachroo (7), S. Chris Malaisrie (8), Dianna Milewicz (9), Michael Borger (10), Nicholas Kouchoukos (11), Munir Boodhwani (12), Harry C. Dietz (13), Hartzell Schaff, MD (3), Nimesh Desai (14), Marc Moon (1), Joseph Coselli (1)
Institutions
(1) Baylor College of Medicine, Houston, TX, (2) Stanford University School of Medicine, Stanford, CA, (3) Mayo Clinic, Rochester, MN, (4) Geisinger Medical Center: Heart Institute, Danville, PA, (5) Harvard University, Boston, MA, (6) Weill Cornell Medical Center, New York, NY, (7) Washington University School of Medicine, Saint Louis, MO, (8) Northwestern Memorial Hospital, Chicago, IL, (9) McGovern Medical School at UTHealth Houston, Houston, TX, (10) University of Leipzig, Leipzig, Germany, (11) Washington University Medical Center, Saint Louis, MO, (12) University of Ottawa Heart Institute, Ottawa, Canada, (13) Johns Hopkins School of Medicine, Baltimore, MD, (14) University of Pennsylvania, Philadelphia, PA
Aortic Symposium
Aortic Root