Optimal Treatment Timing for Type B Aortic Dissections

Branson Taheri Poster Presenter
University of Colorado Anschutz Medical Center
Denver, CO 
United States
 - Contact Me

Branson Taheri is a third-year vascular surgery resident at the University of Colorado.

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Introduction: The utility of endovascular repair for Type B Aortic Dissection (TBAD) is well described both for complicated dissections and dissections with high-risk features. While the optimum timing of repair is thought to be in the subacute period from two weeks to three months after dissection, there is limited data that compares outcomes of this timing with operating in an acute period.

Methods: This retrospective cohort analysis identified cases of thoracic endovascular aortic repair (TEVAR) at our institution form Oct 2015-Oct 2025. We included all cases of TEVARS done for TBAD in either the acute or subacute dissection period, and we compared demographics and outcomes between the acute and subacute cohorts.

Results: The total study cohort consisted of 60 patients with 39 patients treated in the acute period and 21 in the subacute period. There were no significant demographic differences between the two groups. There were also no significant differences in post-operative landing zone degenerations, aortic degenerations distal to the TEVAR site, proximal open reinterventions, distal open reinterventions, or reinterventions for endoleaks. These results are shown in Table 1. The two cohorts did not have a significant difference in 30-day or overall mortality by Kaplan-meier analysis (p = 0.32 and p = 0.25 respectively).

Conclusion: Our data suggests that survival and aortic outcomes are similar between patients treated with TEVAR in the acute and subacute dissection periods. When patients require TEVAR in the acute dissection period due to malperfusion or concern for lack of follow up, our experience suggests that it is safe to do so. However, these results should be interpreted with caution given the overall small sample size of our study cohort.

Authors
Branson Taheri (1), Bo Chang Wu (2), Rafael Malgor (3), Muhammad Aftab (4), T. Brett Reece (5)
Institutions
(1) University of Colorado Anschutz Medical Center, Denver, CO, (2) University of Colorado Anschutz Medical Center, Aurora, CO, (3) University of Colorado Anschutz, Denver, CO, (4) University of Colorado Anschutz Medical Center and Rocky Mountain Regional VAMC, Aurora, CO, (5) University of Colorado Hospital, Aurora, CO

Aortic Symposium

Dissection