Stent-in-Stent Frozen Elephant Trunk Reconstruction for Persistent False-Lumen Perfusion After Acute Type A Aortic Dissection Repair

Silvia Di Sibio Poster Presenter
Fondazione Toscana Gabriele Monasterio
La Spezia, La Spezia 
Italy
 - Contact Me

Silvia Di Sibio, MD, is a cardiac surgeon specializing in adult cardiac surgery, with a particular interest in thoracic aortic disease and hybrid and endovascular approaches. She graduated in Medicine and Surgery from the University of Pisa and completed her residency in Cardiac Surgery at the University of Florence in 2023, both with honors.

She is currently a PhD candidate in Translational Medicine at Scuola Superiore Sant’Anna in Pisa, where her research focuses on the relationship between aortic stenosis and cardiac amyloidosis. Her clinical and scientific interests include aortic surgery, complex aortic arch repair, and innovative hybrid techniques. She has authored and co-authored several scientific publications in the field of cardiovascular surgery.

Thursday, November 19, 2026: 6:03 AM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Objective: Persistent false-lumen perfusion after hybrid stent-supported repair of acute type A aortic dissection may cause adverse remodeling and require secondary intervention. We describe redo total arch replacement with stent-in-stent frozen elephant trunk reconstruction and an unusual imaging finding of suspected metallic scaffold disruption.
Methods: A 55-year-old woman underwent emergency biological root, ascending aortic, and limited arch replacement with a non-covered hybrid arch dissection stent for acute type A dissection complicated by severe aortic regurgitation and neurological malperfusion. Serial computed tomography showed persistent false-lumen perfusion and progressive thoracic aortic enlargement. Seventeen months later, a frozen elephant trunk prosthesis was deployed within the previous scaffold under fluoroscopic guidance and expanded by balloon dilatation. The brachiocephalic and left common carotid arteries were reimplanted. An extra-anatomic left axillary bypass and staged endovascular occlusion of the native left subclavian origin completed the reconstruction.
Results: The proximal thoracic aorta enlarged from 43 to 46 mm, the mid-descending segment from 29 to 35 mm, and the distal segment from 27 to 30 mm, with persistent false-lumen opacification. Retrospective imaging review showed marked scaffold deformation and apparent focal discontinuity of several metallic struts, suggestive but not diagnostic of structural disruption. Its relationship with adverse remodeling remained uncertain. Reconstruction was technically successful. Postoperative haemothorax and cardiac subtamponade required mediastinal re-exploration. The patient recovered without new focal neurological deficits, with preserved ventricular function and a normally functioning biological aortic prosthesis.
Conclusions: Persistent false-lumen perfusion after hybrid stent-supported repair may cause progressive thoracic aortic enlargement. Redo total arch replacement with stent-in-stent frozen elephant trunk reconstruction is technically feasible. Fluoroscopic guidance and balloon-assisted expansion facilitate controlled deployment and stent-to-stent apposition. Longitudinal imaging should assess both aortic remodeling and scaffold integrity; suspected structural abnormalities require cautious interpretation until confirmed.

Authors
Silvia Di Sibio (1), Tommaso Gasbarri (2), Michele Murzi (3), Pierandrea Farneti (4), Marco Solinas (5)
Institutions
(1) Fondazione Toscana Gabriele Monasterio, La Spezia, La Spezia, (2) Ospedale Del Cuore Fondanzione Gabriele Monasterio, Massa, NA, (3) Fondazione Toscana Gabriele Monasterio, Forte dei Marmi, Lucca, (4) N/A, Massa, Italy, (5) Fondazione Toscana Gabriele Monasterio, Massa, Massa and Carrara

Aortic Symposium

Aortic Arch