Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square
Room: Exhibit Hall & Metropolitan Ballroom
Objective
Current guidelines recommend intervention for ascending aortic aneurysm at a maximal diameter of 5.5 cm. The 2022 ACC/AHA aortic guidelines acknowledge the importance of non‑diameter indices: aortic size index (ASI), aortic height index (AHI), and indexed aortic area (IAA) as alternative parameters for surgery.
Our objective was to evaluate these non-diameter indices in patients with ascending thoracic aortic aneurysms of 4.5-5.5cm.
Methods
We conducted a single‑centre, retrospective analysis of 124 patients from 2019–2024 undergoing first‑time elective surgery for ascending aneurysm ± aortic valve intervention, with preoperative CT scans confirming maximal diameters of 4.5–5.5 cm.
The patients' height, weight, body mass index (BMI, H / W2) and body surface area (BSA √[(H x wt) / 3600)] were recorded. Aortic diameters were measured at the annulus, sinus of Valsalva, sinotubular junction and mid‑ and distal ascending aorta. The largest diameter (D) and height H (m) were used to calculate ASI (D / BSA), AHI (D/H), and IAA [π × (D / 2)² / H].
Results
The median age was 59.5 years, and 71% were male. The median aortic diameter was 4.79 cm. Aortic index parameters varied substantially across the cohort. ASI and AHI each identified only 3.2% of patients, whereas IAA >10 cm²/m identified 33.1% (p<0.0001).
Comparing males and females, median aortic diameters were similar, but women had significantly smaller body size, with lower BSA and height (BSA 2.11 vs 1.86 m²; height 177.8 vs 166.1 cm; p<0.001). These differences resulted in higher indexed aortic values among women (ASI 2.56 vs 2.34 cm/m²; IAA 9.81 vs 9.02 cm²/m; p<0.03).
Conclusion
In patients with ascending aneurysms of 4.5–5.5 cm, 39% of patients exceeded at least one aortic index threshold (ASI >3.08 cm/m², AHI ≥3.21 cm/m, IAA >10 cm²/m).
IAA captured a large subset of patients whose diameters remained below the traditional 5.5 cm threshold. IAA is a significantly more sensitive discriminator of surgical eligibility than ASI or AHI, particularly in women. The data suggests that reliance on diameter alone underestimates risk in a distinct population and supports integrating IAA into operative decision making for ascending aneurysms between 4.5-5.5cm.
Authors
Kevin Sales (1), Eleonora De Laurentis (1), Vinci Naruka (1), Robert Morgan (1), Marjan Jahangiri (1)
Institutions
(1) St George’s University Hospital NHS Foundation Trust London, London, United Kingdom
Aortic Symposium
Aortic Surgery Forum (Basic Aortic Research, Venue for Residents, Fellows, Junior Attendings)