Development of real-time, high-fidelity physiologic cerebral monitoring during aortic arch surgery

Lauren Levy Poster Presenter
University of Utah
Holladay, UT 
United States
 - Contact Me

PGY-5 Integrated Thoracic Surgery resident at the University of Utah. 

My research is supported by the National Institutes of Health under Ruth L. Kirschstein National Research Service Award T32HL007576 from the National Heart, Lung, and Blood Institute.

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Objective: While Near-Infrared Spectroscopy (NIRS) cerebral oximetry is the most common method for estimating regional cerebral perfusion during circulatory arrest (CA) for aortic surgery, it is a low-fidelity technique that may not fully capture frontal brain cerebral activity. Frontal electroencephalogram (EEG), however, directly monitors frontal cortex function. We assessed frontal EEG compared to NIRS cerebral oximetry during elective aortic arch surgery as a high-fidelity method for monitoring cerebral perfusion.
Methods: Five patients underwent elective ascending aorta plus total or partial arch replacement at a single institution from April-July 2026. Cardiopulmonary bypass (CPB) was established via aorta-right atrial cannulation; CA was performed at moderate hypothermia (24-28°C) with bilateral antegrade cerebral perfusion (ACP). Frontal EEG and NIRS cerebral oxygen saturation (StO2) were monitored simultaneously throughout surgery.
Results: Four patients underwent hemiarch and one underwent total arch replacement. Mean age was 56.4 ± 14.5 years. 60% were male. Mean BMI was 30.9 ± 7.4 kg/m2. 80% had hypertension, hyperlipidemia, and were nonsmokers. No patients had cerebrovascular disease or carotid stenosis. Two patients underwent bio-Bentall root replacement for moderate+ aortic stenosis (AS); one had an aortic valve replacement for mixed moderate AS/aortic insufficiency (AI), and one underwent aortic valve repair for mild AI. The total arch patient also underwent frozen elephant trunk placement. Mean CPB, aortic cross-clamp, and CA times were 246.4 ± 26.0, 142.2 ± 50.1, and 26.0 ± 10.1 minutes, respectively. During cooling and CA with ACP, frontal EEG demonstrated a change in brain activity from broad spectral activity to predominantly low-frequency activity corresponding to delta and theta waves in four patients, indicating slowing of frontal cortical electrical activity and correlating with observed decreases in NIRS cerebral StO2. In Patient #3, frontal EEG demonstrated burst suppression correlating to intra-operative stroke that was not detected by NIRS.
Conclusions: Frontal EEG may provide more sensitive, real-time cerebral monitoring than NIRS cerebral oximetry during aortic arch surgery including capture of massive neurological events. This pilot study demonstrates equipoise for using frontal EEG as a standardized cerebral monitoring method in future prospective trials investigating neurologic outcomes during aortic arch surgery.

Authors
Lauren Levy (1), Srdjan Dragovic (1), Jason Glotzbach (1), Christian Guay (1), Andrea Steely (1)
Institutions
(1) University of Utah, Salt Lake City, UT

Aortic Symposium

Anesthesia and Perioperative Management