William MacDonald is a fourth-year medical student at Columbia University Vagelos College of Physicians and Surgeons. He is interested in cardiothoracic surgery and conducts aortic surgery outcomes research with Hiroo Takayama, MD, PhD at NewYork-Presbyterian/Columbia. William is from Leipzig, Germany, and is a graduate of Brown University.

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Objective: Plication of the sinotubular junction (STJ) during ascending aortic replacement may preserve or restore aortic valve (AV) function. We assessed four-year outcomes of a novel technique of patient-specific double-layer STJ plication.

Methods: From 2019 to 2025, 72 patients underwent ascending aortic repair with patient-specific STJ plication for STJ effacement due to acute type A dissection (n=40) or aneurysm (n=32), with or without associated aortic regurgitation (AR). To secure the STJ at a target diameter, a short everted Dacron graft ring is secured at the commissures with mattress sutures and plicated over a Hegar dilator to a patient-specific target diameter, based on body size and valve inspection (Fig. 1A). Primary endpoints were cumulative incidence of ≥moderate AR and AV reintervention. STJ targets were validated post hoc through guideline-derived, body surface area (BSA) indexing: STJ (cm) = 0.62*BSA+1.69.

Results: Mean preoperative STJ diameter was 37.1±5.1 mm. Mean target diameter was 27.2±0.9 mm, with stable postoperative (26.9±1.8 mm) and follow-up diameters (Fig. 1B); 61 (84.7%) target diameters were within 3 mm of BSA-predicted diameter. Preoperative AR was
Conclusions: Patient-specific plication showed stable STJ diameters and no STJ-effacement-mediated AR in follow-up. Four-year rates of AR and AV reintervention are encouraging and comparable to existing supracoronary techniques. Advantages include excellent hemostasis, long-term mechanical stability, and secure reattachment of dissected layers, promoting favorable aortic remodeling. BSA-derived STJ diameters can aid a priori target selection.

Authors
William MacDonald (1), Megan Chung (1), Yuichiro Kitada (1), Yanling Zhao (1), Yu Hohri (1), Valeria Jimenez (1), Benjamin S. van Boxtel (2), Paul Kurlansky, MD (3), Adham Elmously (1), Hiroo Takayama (1)
Institutions
(1) NewYork- Presbyterian/Columbia University Medical Center, New York, NY, (2) Morristown Medical Center, Morristown, NJ, (3) Center for Innovation and Outcomes Research, New York Presbyterian Hospital/Columbia University, New York, NY