Y-Incision Aortic Annular Enlargement as a Platform for Future ViV TAVI
Joshua Schwartz
Poster Presenter
Emory Saint Joseph's Hospital
Atlanta, GA
United States
-
Contact Me
Dr. Joshua Schwartz, MD, MPH, FRCSC, is an advanced fellow in robotic cardiac surgery at Emory University. He completed his integrated cardiac surgery residency at McGill University and earned a Master of Public Health at the Harvard T.H. Chan School of Public Health, focusing on epidemiology and biostatistics.His clinical interests include reconstructive valve surgery, minimally invasive coronary revascularization, and aortic surgery. His academic interests include surgical education and clinical outcomes research.
Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square
Room: Exhibit Hall & Metropolitan Ballroom
Objective
Patient-prosthesis mismatch (PPM) is a limitation of surgical aortic valve replacement (SAVR), particularly in patients with a small aortic annulus. Y-incision aortic annular enlargement (AAE) permits implantation of larger surgical prostheses. We examined mid-term hemodynamics and feasibility of valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) post SAVR with AAE.
Methods
From November 2021 to February 2025, 31 consecutive patients underwent SAVR with Y-incision AAE at the Royal Victoria Hospital. Clinical and echocardiographic follow-up was 100% complete. Postoperative imaging assessed prosthetic valve hemodynamics, PPM, and suitability for future ViV TAVI.
Results
Mean age was 70 ± 7 years, 65% were female, and mean body mass index was 31 ± 9 kg/m². There was no 30-day mortality and two late non-cardiac deaths occurred (6.5%). AAE increased median left ventricular outflow tract (LVOT) diameter from 20 ± 2 to 24 ± 2 mm, with 25 of 31 patients receiving prostheses with internal diameters larger than their native LVOT. At a median follow-up of 2.6 years, median (IQR) indexed effective orifice area was 0.9 cm² (0.8–1.0), with a mean transvalvular gradient of 11 mm Hg (7–16). Using manufacturer charts intra-operatively, 61% of patients were predicted to develop PPM. Following AAE and implantation of a larger prosthesis, 7 patients (23%) had moderate PPM and 2 (6%) had severe PPM at follow-up. At baseline, 10 of 19 patients (53%) who underwent TAVI assessment had unsuitable anatomy. Following AAE, 24 of 27 patients (89%) with postoperative scans assessed had suitable anatomy for ViV TAVI. Predicted median (IQR) valve size was 29 (26–29) mm for Evolut and 26 (23–26) mm for Sapien.
Conclusion
Y-incision AAE enables implantation of larger surgical prostheses in patients with small aortic annuli, resulting in favorable mid-term hemodynamics and a lower incidence of PPM than predicted. By creating a larger surgical valve platform, AAE may facilitate implantation of an appropriately sized ViV TAVI, expanding options for lifetime management of valve disease.
Authors
Joshua Schwartz (1), Adel Alqabandi (1), Tara D'Ignazio (1), Ibrahim Alranini (1), Abdulrahman Alhalees (1), Jean Buithieu (1), Josephine Pressacco (1), Giuseppe Martucci (1), Kevin Lachapelle (1)
Institutions
(1) McGill University, Montreal, Canada
Aortic Symposium
Aortic Root
You have unsaved changes.