Development of a Scoring System to Predict Access Site Complications in Thoracic Endovascular Aortic Repair

Branson Taheri Poster Presenter
University of Colorado Anschutz Medical Center
Denver, CO 
United States
 - Contact Me

Branson Taheri is a third-year vascular surgery resident at the University of Colorado.

Thursday, November 19, 2026: 6:03 AM - Friday, November 20, 2026: 6:03 PM
Sheraton Times Square 
Room: Exhibit Hall & Metropolitan Ballroom 

Description

Objective: The advent of endovascular repair for thoracic aortic pathology has revolutionized treatment paradigms with minimally invasive strategies. However, access site complications during thoracic endovascular aortic repair (TEVAR) remains a persistent problem.

Methods: We identified all patients who underwent TEVAR by transfemoral access at a single institution from 2020 – 2025. We compared pre-operative and operative characteristics between those who had an access complication and those who did not. Variables with a trend towards a significant difference (p < 0.2) were incorporated into a scoring system to predict an access related complication that was analyzed with receiver operating characteristic analysis.

Results: Our final study cohort consisted of 262 patients who had sufficient data available for analysis. Among these, 28 patients had an access complication (10.7%). Those with an access related complication were older (mean age 67.5 vs. 61.7, p = 0.018), were less likely to be of male gender (39.3% vs. 70.1%, p = 0.002), and had higher delivery device sheath sizes (mean 22.1 french vs. 21.2 french, p = 0.015). Additionally, we included pre-operative dialysis (p = 0.126) and aneurysm procedure indication into our scoring system (p = 0.195). In this system we allocated one-point for age greater than or equal to 75, female gender, delivery device sheath size at least 22 french, aneurysm procedure indication, and pre-operative dialysis. Receiving at least two points in this system had a sensitivity of 75% and a specificity of 63%. The full receiver operating characteristic curve for this scoring system is shown in Figure 1 with an area under the curve of 0.73.

Conclusion: These data show how increasing age, increasing delivery device size, and female gender are all predictive of access related complications. We developed a scoring system to predict these issues with a moderate degree of accuracy that may be used to better counsel patients or determine when a planned, initial open femoral exposure may be indicated.

Authors
Branson Taheri (1), Bo Chang Wu (2), Elizabeth Bashian (2), Gregory Fishberger (3), Meng Han Tsai (3), Rafael Malgor (4), Muhammad Aftab (5), T. Brett Reece (6)
Institutions
(1) University of Colorado Anschutz Medical Center, Denver, CO, (2) University of Colorado Anschutz Medical Center, Aurora, CO, (3) University of Colorado, Anschutz Medical Center, Aurora, CO, Aurora, CO, (4) University of Colorado Anschutz, Denver, CO, (5) University of Colorado Anschutz Medical Center and Rocky Mountain Regional VAMC, Aurora, CO, (6) University of Colorado Hospital, Aurora, CO

Aortic Symposium

Endoluminal Prostheses